2.1 SNMP Protocol MIB Definition 

No.

 

OID

 

Content 

 

R/W Authority

 

Value Type

 

HFA Definition

 

1

 

1.3.6.1.4.1. 27304.89.2.1

 

SN

 

Read Only

 

String

 

2

 

1.3.6.1.4.1. 27304.89.2.2

 

TYPE

 

Read Only

 

String

 

3

 

1.3.6.1.4.1. 27304.89.2.3

 

Working mode

 

Read Only

 

String

 

4

 

1.3.6.1.4.1. 27304.89.2.4

 

Input optical power value

 

Read Only

 

String

 

5

 

1.3.6.1.4.1. 27304.89.2.5

 

Input optical power los alarm threshold Read & Write

 

String

 

6

 

1.3.6.1.4.1. 27304.89.2.6

 

Input optical power low alarm threshold Read & Write

 

String

 

 

7

 

 

1.3.6.1.4.1. 27304.89.2.7

 

Input optical power high alarm 
threshold

 

 

Read & Write

 

 

String

 

8

 

1.3.6.1.4.1. 27304.89.2.8

 

Set output optical power

 

Read & Write

 

String

 

9

 

1.3.6.1.4.1. 27304.89.2.9

 

Output optical power value

 

Read Only

 

String

 

 

10

 

 

1.3.6.1.4.1. 27304.89.2.10

 

Output optical power los alarm 
threshold

 

 

Read &Write

 

 

String

 

11

 

1.3.6.1.4.1. 27304.89.2.11

 

Output optical power low alarm 
threshold 

 

Read &Write

 

String

 

12

 

1.3.6.1.4.1. 27304.89.2.12

 

Output optical power high alarm 
threshold

 

Read &Write

 

String

 

13

 

1.3.6.1.4.1. 27304.89.2.13

 

Case temperature

 

Read Only

 

String

 

14

 

1.3.6.1.4.1. 27304.89.2.14

 

Pump1 power

 

Read Only

 

String

 

15

 

1.3.6.1.4.1. 27304.89.2.15

 

Pump1 bias current

 

Read Only

 

String

 

16

 

1.3.6.1.4.1. 27304.89.2.16

 

Pump1 tec current

 

Read Only

 

String

 

17

 

1.3.6.1.4.1. 27304.89.2.17

 

Pump1 temperature

 

Read Only

 

String

 

18

 

1.3.6.1.4.1. 27304.89.2.18

 

Pump2 power

 

Read Only

 

String

 

19

 

1.3.6.1.4.1. 27304.89.2.19

 

Pump2 bias current

 

Read Only

 

String

 

20

 

1.3.6.1.4.1. 27304.89.2.20

 

Pump2 tec current

 

Read Only

 

String

 

21

 

1.3.6.1.4.1. 27304.89.2.21

 

Pump2 temperature

 

Read Only

 

String

 

22

 

1.3.6.1.4.1. 27304.89.2.22

 

Pump3 power

 

Read Only

 

String

 

23

 

1.3.6.1.4.1. 27304.89.2.23

 

Pump3 bias current

 

Read Only

 

String

 

24

 

1.3.6.1.4.1. 27304.89.2.24

 

Pump3 tec current

 

Read Only

 

String

 

25

 

1.3.6.1.4.1. 27304.89.2.25

 

Pump3 temperature

 

Read Only

 

String

 

26

 

1.3.6.1.4.1. 27304.89.2.26

 

Alarm bytes

 

Read Only

 

String

 

27 1.3.6.1.4.1. 27304.89.2.27 

Pump on or off switch 

Read &Write String 

 

Note: 

 

1)

 

  Alarm Bytes (OID: 1.3.6.1.4.1. 27304.89.2.26):   

Value = ALM1*256*256*256+ ALM2 * 256 * 256 + ALM3 * 256 + ALM4 

Example:    ALM1=0x04     ALM2=0 ALM3 = 0x02 ALM4 = 0x00   

Value=4*256*256*256+0*256*256+0x02*256+0x00=04000200(HEX) 

Summary of Contents for High-power Fiber Amplifier

Page 1: ...High power Fiber Amplifier Network Management Interface Operation Manual ver 1 0...

Page 2: ...ents 1 Revision History 2 Introduction 3 Operation Manual 3 1 Web Service 3 1 1 HFA Monitor 3 1 2 Status 4 1 3 Network 5 1 4 DNS 6 1 5 SNMP 7 1 6 System 8 1 7 Password 9 2 SNMP 10 2 1 SNMP Protocol MI...

Page 3: ...Page 2 of 14 Revision History Revision Date Description 1 0 20120428 Initial release...

Page 4: ...e enables online configuration of the products and offers customers good maneuverability Operation Manual 1 Web Service Function Web Server in HFA Device provides Http operating interface which allows...

Page 5: ...Page 4 of 14 Figure 2 1 2 Status Click Status to read the current parameters of the device such as IP address MAC etc see Figure 3 Figure 3...

Page 6: ...current running configuration and the other shows the configuration that will take effect after the device is rebooted The following items are required for the reboot to take effect z DHCP Client On...

Page 7: ...5 This page displays the current configuration of the DNS subsystem Users may configure the Primary and Secondary static server addresses by themselves If the current configuration shows the address...

Page 8: ...Page 7 of 14 1 5 SNMP Click SNMP to read and write the parameters of HFA via SNMP manager see Figure 6 Figure 6...

Page 9: ...n this web page see Figure 7 It will take a few minutes to update program please be patient for it Figure 7 Be careful not to power off or reset the device while uploading new firmware Once the upload...

Page 10: ...14 1 7 Password Click Password Button to change user password in this web page see Figure 8 Note that users may start a new browser to access the device if the password of user is changed successfully...

Page 11: ...e parameters of HFA via SNMP manager Default read community public Default write community admin The SNMP Agent located on the device follows standard SNMPv2 protocol Users can read or write the OIDs...

Page 12: ...old Read Write String 13 1 3 6 1 4 1 27304 89 2 13 Case temperature Read Only String 14 1 3 6 1 4 1 27304 89 2 14 Pump1 power Read Only String 15 1 3 6 1 4 1 27304 89 2 15 Pump1 bias current Read Only...

Page 13: ...Bit value 1 Alarm 0 Normal or Reserved 2 2 Alarm Trap Definition Oid1 Type Oid2 Current value Describe Trap CaseTemp High Alarm 1 3 6 1 4 1 27304 89 4 1 Case temperature High Alarm CaseTemp High Recov...

Page 14: ...2 9 Output Power Recovery Pump temp Alarm 1 3 6 1 4 1 27304 89 4 17 Pump temperature Alarm Pump temp Recovery 1 3 6 1 4 1 27304 89 4 18 1 3 6 1 4 1 27304 89 2 26 Alarm Bytes Recovery Pump ild Alarm 1...

Page 15: ...1 27304 89 4 30 Recovery Power Supply 1 alarm 1 3 6 1 4 1 27304 89 4 31 Power supply 1 alarm Power Supply 1 alarm recovery 1 3 6 1 4 1 27304 89 4 32 Recovery Power Supply 2 alarm 1 3 6 1 4 1 27304 89...