High-power Fiber Amplifier
Network Management Interface
Operation Manual
(ver 1.0)
Page 1: ...High power Fiber Amplifier Network Management Interface Operation Manual ver 1 0...
Page 2: ...ents 1 Revision History 2 Introduction 3 Operation Manual 3 1 Web Service 3 1 1 HFA Monitor 3 1 2 Status 4 1 3 Network 5 1 4 DNS 6 1 5 SNMP 7 1 6 System 8 1 7 Password 9 2 SNMP 10 2 1 SNMP Protocol MI...
Page 3: ...Page 2 of 14 Revision History Revision Date Description 1 0 20120428 Initial release...
Page 4: ...e enables online configuration of the products and offers customers good maneuverability Operation Manual 1 Web Service Function Web Server in HFA Device provides Http operating interface which allows...
Page 5: ...Page 4 of 14 Figure 2 1 2 Status Click Status to read the current parameters of the device such as IP address MAC etc see Figure 3 Figure 3...
Page 6: ...current running configuration and the other shows the configuration that will take effect after the device is rebooted The following items are required for the reboot to take effect z DHCP Client On...
Page 7: ...5 This page displays the current configuration of the DNS subsystem Users may configure the Primary and Secondary static server addresses by themselves If the current configuration shows the address...
Page 8: ...Page 7 of 14 1 5 SNMP Click SNMP to read and write the parameters of HFA via SNMP manager see Figure 6 Figure 6...
Page 9: ...n this web page see Figure 7 It will take a few minutes to update program please be patient for it Figure 7 Be careful not to power off or reset the device while uploading new firmware Once the upload...
Page 10: ...14 1 7 Password Click Password Button to change user password in this web page see Figure 8 Note that users may start a new browser to access the device if the password of user is changed successfully...
Page 11: ...e parameters of HFA via SNMP manager Default read community public Default write community admin The SNMP Agent located on the device follows standard SNMPv2 protocol Users can read or write the OIDs...
Page 12: ...old Read Write String 13 1 3 6 1 4 1 27304 89 2 13 Case temperature Read Only String 14 1 3 6 1 4 1 27304 89 2 14 Pump1 power Read Only String 15 1 3 6 1 4 1 27304 89 2 15 Pump1 bias current Read Only...
Page 13: ...Bit value 1 Alarm 0 Normal or Reserved 2 2 Alarm Trap Definition Oid1 Type Oid2 Current value Describe Trap CaseTemp High Alarm 1 3 6 1 4 1 27304 89 4 1 Case temperature High Alarm CaseTemp High Recov...
Page 14: ...2 9 Output Power Recovery Pump temp Alarm 1 3 6 1 4 1 27304 89 4 17 Pump temperature Alarm Pump temp Recovery 1 3 6 1 4 1 27304 89 4 18 1 3 6 1 4 1 27304 89 2 26 Alarm Bytes Recovery Pump ild Alarm 1...
Page 15: ...1 27304 89 4 30 Recovery Power Supply 1 alarm 1 3 6 1 4 1 27304 89 4 31 Power supply 1 alarm Power Supply 1 alarm recovery 1 3 6 1 4 1 27304 89 4 32 Recovery Power Supply 2 alarm 1 3 6 1 4 1 27304 89...