1834-065-B-10-14
49
1.
Press and enter your four-digit MASTER CODE (
beep
).
2.
Press (
beep
).
PASS
- The LCD display will indicate:
RS232 HARDWARE PASS
. One long tone will be heard: (
Beeeeeep
).
FAIL
- The LCD display will indicate
RS232 HARDWARE FAIL
. Two short tones and a long tone will be heard:
(
Beep
-
Beep
-
Beeeeeep
).
3.
Remove the jumper wires from the terminal after performing this test.
??
??
??
??
77
PQRS
PQRS
11
SP
SP
6.1.1 RS-232 Test
This test procedure will check the RS-232 hardware to determine a
PASS
or
FAIL
mode. You will need two short pieces of wire
to perform this test (jumpers). Connect the jumper wires as shown to the RS-232 terminal.
1
2
3
4
5
6
RS-232 Terminal
Red
Black
White
Brown
Green
Shield
The 6-pin terminal
can be removed
for easy wiring.
RS-232
DB-9 Pin
Plug
This sequence will allow you to program different methods by which the telephone entry system will hang-up if a resident
denies a guest access by hanging up their telephone rather than pressing the “
#
” key to terminate the call.
Factory setting is 1, dial tone detect ON.
1.
Press and enter your four-digit MASTER CODE (
beep
).
The LCD display will show:
0=N 1=DT 2=SIL 3=BTH.
0 – BOTH OFF.
Unit hangs up after programmed strike time runs out.
1 – DIAL TONE detect ON.
Unit hangs up after detecting 5-seconds of dial tone.
2 –SILENCE detect ON.
Unit hands up after detecting 15-seconds of silence.
3 – BOTH ON.
2.
Enter the
hang-up option code
_ (0, 1, 2 or 3), then press (
beep
).
3.
Press TOGETHER to end this programming sequence (
beeeeeep
).
??
??
??
??
00
OPER
OPER
44
GHI
GHI
00
OPER
OPER
6.1.2 Automatic Hang-up Options