background image

NANO-TEC

 

Bruger Manual

 

 

 

DK Online A/S

 

 

   

 55

 

8.2 

LAST RECEIPT COPY PRINT 

 

To print a copy of the last registered transaction, press:  

 

 
 

 

 

* *   R E C E I P T   C O P Y   * *  

ECR S/N: 00000000 

REC

#00000043  

 
← Copy indication

 

 

CLERK JANE 

 

 

 

DEP 01 

5.50A 

 

 

TOTAL SGD 

5.50 

 

 

CASH 

5.50 

 

 

 

 

 

Date →

 

03.08.2009 

14:54 

← Time 

 

THANK YOU! 

 

 

 

 

 

Sample issued in receipt copy operation 

 

 

 

Summary of Contents for NANO-TEC

Page 1: ...BRUGER MANUAL MOBIL ELEKTRONISK KASSEAPPARAT NANO TEC...

Page 2: ...heder til at foretage ndringer i specifikationerne uden varsel Denne publikation eller dele heraf m ikke reproduceres i nogen form uden forudg ende skriftlig tilladelse fra DK Online A S Uautoriseret...

Page 3: ...3 ACCESORIES 12 3 3 1 STANDARD ACCESSORIES 12 3 4 EXTERNAL EQUIPMENT AND PC CONNECTION 12 3 5 ELECTRONIC JOURNAL FUNCTION 13 3 6 PAPER ROLL CHANGE 13 3 7 KEYBOARD 14 3 8 KEY FUNCTIONS 14 3 9 OPERATING...

Page 4: ...RS 43 7 7 3 SPLIT TENDERS 44 7 7 4 FOREIGN CURRENCY PAYMENT 45 7 8 ERROR CORRECTIONS 46 7 8 1 LAST ENTERED ITEM CANCEL 47 7 8 2 PREVIOUS REGISTRATION CANCEL 48 7 8 3 NON FINALIZED SALE CANCEL 49 7 9 R...

Page 5: ...igt denne vejledning ikke tillader utr net personale til at betjene dette kasseapparat ikke bruger kasseapparatet i upassende milj Brug kun godkendte papirruller 57 50TERMO 57 mm bred max 50 mm kan k...

Page 6: ...ter den ellers kan du beskadige ledningen og det kan resultere i brand eller elektrisk st d For at undg brand eller elektrisk st d skal du omg ende tage stikket ud af stikkontakten hvis 1 ECR varmer o...

Page 7: ...1 2 TERMS USED IN THIS MANUAL registration the process of a numeral and a function key entry sale the series of item registration which is to be finalized by payment media key numerals keys 1 9 0 00...

Page 8: ...top 7 linjer grafisk logo Logo bund 3 linjer 2 2 ECR PARAMETER Dimension 80 B x 210 D x 60 H mm V gt 480 g Kabinet plastic Kabinet farver Iron Grey Str mforbrug 20W Max 5W stand by Operation temp 0 0...

Page 9: ...r Antal taster 35 standard taster 2 6 BETJENINGS MODE 4Mode PRG programmerings mode REG registerins mode X rapport mode afl ser Z rapport mode Nulstiller 2 7 KOMMUNIKATION Kommunikation Porte 1xUSB 1x...

Page 10: ...Bruger Manual NANO TEC 10 DK Online A S 3 BASIC OPERATION 3 1 ELECTRONIC CASH REGISTER CHD 7...

Page 11: ...ns power supply adapter CHD U95A3 input 100 240V 50 60Hz Output 9V 1A USB PC communications ECRconfigurator COM 1 PC communication barcode scanner or scales Connect ONLY the intended equipment to CHD...

Page 12: ...reduce annoying interference use the recommended accessories ONLY 3 4 EXTERNAL EQUIPMENT AND PC CONNECTION CHD 7 cash register may be connected with PC using USB cable Refer to CHD Ecrconfigurator ma...

Page 13: ...perly in microSD card slot 512MB 4GB miniSD card use is recommended ECR operation can be blocked and its functions prohibited if External data storage is not inserted in the SD card slot or the storag...

Page 14: ...ey Used to allow text comment entries to be printed on receipt anytime during the sale Non Add Number Print No sale key Used to print a non add number on the receipt for future reference and to open t...

Page 15: ...ed to enter payments received on account i e not relating to a sale Also used for change reserve amounts loaned from the store Used for moving upwards the menu items Paid Out Page Down key Used to rec...

Page 16: ...gistered yet or to clear error status after the error condition correction Payment Media key One of additional non cash payment media keys e g CHARGE CREDIT GIFT CERTICIATE etc used to record non cash...

Page 17: ...de without deleting the current readings after print out Z the sale totals printing mode deleting the current readings after print out To switch between operation modes choose the following key sequen...

Page 18: ...TEC 18 DK Online A S 3 10 DISPLAY CHD 7 is equipped with two displays CLERK and CUSTOMER display 3 10 1 CLERK DISPLAY STATUS 1 OUTSIDE SALE 2 DURING SALE 3 PAYMENT CLOSING TRANSACTION a Payment enter...

Page 19: ...tus Battery charging is complete disconnect charger Battery is fully charged Battery is half charged Battery is empty Please charge it Blinking battery symbol Battery is critical emptied Further opera...

Page 20: ...Bruger Manual NANO TEC 20 DK Online A S 3 10 3 CUSTOMER DISPLAY STATUS 1 DURING SALE 2 SUBTOTAL...

Page 21: ...ogramming options are available for example setting time and date Inside sale operations SALE Sale in progress 4 2 OPERATION WARNINGS Message Displayed Explanation Clerk ID number or Clerk key require...

Page 22: ...E15 PLU not found Relevant entry missing in the PLU table The necessary programming configurations have to be carried out No discount programmed E17 DISCOUNT REQ The necessary programming configuratio...

Page 23: ...ant entry missing in the currency table The necessary programming configurations have to be carried out Under tender disable error E34 UNDER TEND Amount tendered must be equal or higher than sale subt...

Page 24: ...ations Display operation error E60 Display error Try to continue work if the error reappears contact authorised service centre Too many registrations E72 Registr too many Close the sales and continue...

Page 25: ...S 25 5 CLERK REGISTRATION Clerk log in takes place entering the clerk code and if requested also the password LOG IN According to system settings password entry can be skipped LOG OUT Clerk Log Out fu...

Page 26: ...RGE OPERATIONS PAYMENT REGISTRATION ERROR CORRECTIONS RETURN OPERATIONS NON ADD NUMBER AND TEXT PRINT 2 OUTSIDE SALE TIME AND DATE DISPLAY LAST RECEIPT COPY PRINT RECEIVED ON ACCOUNT PAID OUT Example...

Page 27: ...P 02 2 10 DEP 02 2 10 DEP 03 5 x 4 10 20 50 Unit Quantity x Price ITEM DISCOUNT Discount title 10 00 2 50 Discounted amount REGISTRATIONS PLU 2 6 00 PLU Registration PLU 1 6 00 EC Error Correct PLU 1...

Page 28: ...Bruger Manual NANO TEC 28 DK Online A S 7 2 ITEM REGISTRATION SAMPLE Below a detailed item registration in the receipt is displayed Item total...

Page 29: ...EGISTRATION DEPARTMENTS The keys for department registration are Use of decimal point for price amount entries is a configurable option Please contact your authorised CHD representative for details Re...

Page 30: ...information These preset departments can be registered in quantity and also as multiple registrations Example Department DEP 01 1 50 Single Registration DEP 08 4 00 Single Registration DEP 08 3 x 3 0...

Page 31: ...ed with manually entered prices prices that differ from the pre set prices or are not pre set at all Example Department DEP 01 5 00 Single Registration DEP 07 4 x 3 50 14 00 Quantity Registration DEP...

Page 32: ...REGISTRATION If department is set as a single item transaction is finalized automatically as a cash sale Example Single Item Department DEP 01 6 x 0 50 3 00 TOTAL SGD 3 00 Total CASH 3 00 Amount Tend...

Page 33: ...fers from the programmed price PLU can have positive as well as negative price values PLUs in the receipt can be registered with PRESET PRICES MANUALLY ENTERED PRICES IN QUANTITY IN MULTIPLE REGISTRAT...

Page 34: ...o register a PLU Using any registration type it is possible to register quantity and or multiple registrations Example PLU PLU 15 1 40 PLU Fixed Price Registration Quantity Registration PLU 54 2 x 2 0...

Page 35: ...PRICE PLU REGISTRATION PLU can be registered entering the price manually Example PLU PLU 15 1 40 PLU Fixed Price Registration Quantity Registration PLU 15 2 x 2 00 4 00 Manual Price Registration Samp...

Page 36: ...tion is finalized automatically as a cash sale Such single item PLUs can be registered with manually entered prices and in the necessary quantity Example Quantity x Manual Price Service 2 x 2 50 5 00...

Page 37: ...EC Bruger Manual DK Online A S 37 7 4 4 PLU NAME AND PRICE DISPLAY Anytime during sale or outside sale check the PLU price on clerk s display when necessary Example Clerk Display PLU name and price di...

Page 38: ...ording to the ECR configuration discounts can be pre set to separate keys and in separate rates or amounts but can be entered manually as well 7 6 SURCHARGE Surcharge option is not preset on CHD 7 by...

Page 39: ...tion in general and entering the rate and amount manually 1 2 Example percent discount manual rate entered Sample issued in item manual discount operation Example discount manual amount entered Sample...

Page 40: ...t discount manual rate entered Sample issued in sale manual discount operation Example subtotal discount manual amount entered Sample issued in sale manual amount discount operation Department registr...

Page 41: ...pre set CASH TENDERS NON CASH TENDERS CHARGE CHECK CREDIT etc IF THE ECR HAS BEEN CORRESPONDINGLY CONFIGURED PAYMENTS CAN BE REGISTERED IN DIFFERENT CURRENCIES Tenders can be also split using differe...

Page 42: ...alized by cash totalled or cash tendered In case of amount tendered payment method the change amount is printed on receipt and displayed on the display Example Sale finalised cash tendered PLU PLU 4 2...

Page 43: ...th additionally programmed functional non cash payment key The amount tendered can be required if the media type is correspondingly configured Example Example Samples issued in non cash tender operati...

Page 44: ...ther payment types e g credit card cheque gift certificate Split tender using multiple payment types According to the situation the necessary payment media can be applied variously Example PLU 15 25 1...

Page 45: ...is obligatory Payments in currencies can be carried out also as split tenders in different currencies and by different payment types within the configured options Example PLU registration PLU 15 52 00...

Page 46: ...R provides the following correction functions CLEAR ERROR CONDITION CLEAR NON REGISTERED ENTRIES Error correct used to cancel LAST ENTERED REGISTRATION LAST ENTERED CHARACTER BACKSPACE FUNCTION FOR TE...

Page 47: ...er Manual DK Online A S 47 7 8 1 LAST ENTERED ITEM CANCEL Key is used to cancel the last registration Example DEP 05 5 00A Last Item Error Correct EC DEP 05 5 00A Sample issued in last item error corr...

Page 48: ...2 PREVIOUS REGISTRATION CANCEL Key is used to cancel registration in an unfinished sale Correction is not available sale finalized paid Example PLU 11 5 00 PLU 56 3 50 Previous Item Error Correct VOID...

Page 49: ...NON FINALIZED SALE CANCEL If the current transaction has to be cancelled before finalizing it press Example PLU 11 500 00 PLU 56 4 50 Cancelled Transaction TRN CANCELED 24 06 2011 14 42 THANK YOU Sam...

Page 50: ...to disable return operation inside started sale transaction thus return can be done outside sale only Please contact your authorised CHD representative for details Example ECR S N 00000000 REC 0000004...

Page 51: ...51 7 10 NON ADD NUMBER PRINT This function is used to print numeric information on the receipt Example PLU 16 3 00A 354286 Non Add Number Sample issued in non add number print In case of mistake to de...

Page 52: ...provided algorithm On each entry key character and number symbols are displayed Press the relevant key as many times as necessary until the desired symbol appears on the display Press the key and hold...

Page 53: ...DK Online A S 53 8 OUTSIDE SALE OPERATIONS Operations outside sale do not produce any items being registered in the receipt These operations include TIME AND DATE DISPLAY LAST RECEIPT COPY PRINT RECEI...

Page 54: ...E AND DATE DISPLAY To see date and time on display press key To return to REG mode press key Time and date display on clerk display If time display is activated then also the client display shows the...

Page 55: ...PY PRINT To print a copy of the last registered transaction press R E C E I P T C O P Y ECR S N 00000000 REC 00000043 Copy indication CLERK JANE DEP 01 5 50A TOTAL SGD 5 50 CASH 5 50 Date 03 08 2009 1...

Page 56: ...le After this operation amount of payment media in the drawer is increased Example ECR S N 00000000 REC 00000043 CLERK JANE RECEIVED ON ACCOUNT Amount CASH 1 x 20 00 20 00 Cash registration Example EC...

Page 57: ...side sale This function reduces drawer s content This operation can be used in case of money collection Example ECR S N 00000000 REC 00000043 CLERK JANE PAID OUT Amount CASH 1 x 5 00 5 00 Cash registr...

Page 58: ...are different Report options 1 daily periodic 2 all data single range Choose X or Z mode to print reports accordingly To open mode select display press Select report mode use and keys which navigate...

Page 59: ...X Z 04 CASH Department Period Range Report X Z starting dep NS end dep NS 04 CASH Single Department Period Report X Z department NS 04 CASH PLU Report X Z 05 CASH PLU Range Report X Z starting dep NS...

Page 60: ...CASH Preset report list X Z 61 CASH or larger report list CASH Singe Receipt Copy from EJ X Rec No NS 70 CASH Range Receipt Copy from EJ X starting NS end NS 70 CASH System information Report X 0 CASH...

Page 61: ...TAXABLE WT TOTAL 108 14 Amount with tax TAXABLE WO TOTAL 101 07 GST TOTAL 7 07 NON TAXABLE 1 70 Sales Information SALES Daily Sales Quantity NET SALES 13 109 84 Daily Sales Total Amount NEGATIVE TRANS...

Page 62: ...Amount Grant Total GRAND TOTAL GT 111 84 Grand Total Corrections CORRECTIONS ITEM VOID 3 10 20 Corrected Item Quantity Amount ERROR CORRECTION 1 5 00 Cancelled Last Item REFUNDS 1 2 00 Returned Item C...

Page 63: ...REC 00000043 X1 Report mode Department Report DEPARTMENTS DEP 01 56 423 41 Department name Q ty Amount DEP 02 16 1025 71 Department name Q ty Amount DEP 03 7 29 42 Department name Q ty Amount DEPARTM...

Page 64: ...mple Receipt Header ECR S N 00000000 REC 00000043 CLERK01 X2 Report mode PLU Report PLU 345 PLU Code CHOCOLATE 2 10 00 PLU Name Quantity Amount 57 ICE CREAM 20 122 45 468 WINE 25 250 00 789 MILK 2 22...

Page 65: ...ORT SAMPLE Hourly report sample Receipt header ECR S N 00000000 REC 00000043 CLERK01 X1 Report mode Hourly Report HOURLY 14 00 14 59 28 1478 54 Period Quantity Amount 15 00 15 59 2 15 56 16 00 16 59 1...

Page 66: ...SAMPLE Receipt header ECR S N 00000000 REC 00000043 CLERK01 X1 Report mode Media In Drawer IN DRAWER CASH SGD 100 00 Cash in Drawer CARD SGD 10 00 Credit in Drawer IN DRAWER TOTAL 110 00 Total in Dra...

Page 67: ...ITEM VOID 1 2 42 Items Cancelled MODIFIER VOID 0 0 00 Modifiers cancelled ERROR CORRECT 1 5 75 Items corrected REFUNDS 0 0 00 Items Returned CLERK 02 JANE Clerk ID Name GROSS SALES 6 46 46 Gross Sale...

Page 68: ...N 2 44 0 Alpha Version F LOADER CHDLDR02 Firmware loader DEVICE CHD7 Device name COUNTRY SINGAPORE Country BUILD DATE Apr 3 2012 Build date BUILD TIME 08 31 34 Build time SVN REV 28338 Revision No PCB...