To set the PPM reference level:
1
Perform Steps 1 through 5 under Selecting Preferred
PPM scale.
2
After you press
[SELECT]
, press the function keys for
and
to set the reference level.
3
After you set the level, press
[EXIT]
to return to the
Main Menu.
4.8.3 U
SING THE
LED O
VERLOAD
I
NDICATORS
When an overload condition occurs, the following
indicators activate simultaneously:
•
Two red LED overload indicators in the front plate
illuminate.
•
Split bars appear in the PPM bars in the LCD display.
The LED indicators, located directly above the PPM bars,
light up when the selected reference level for the scale is
reached (for example at +6dB for Type I, Nordic scale).
4.8.4 U
SING THE
PPM P
EAK
H
OLD
F
UNCTION
The Peak HOLD function enables you to check the
maximum signal level reached during and after a
recording session. This helps you confirm that levels did
not exceed specified limits.
In the HOLD mode, the “flying” segments of the PPM bars
indicate the highest bar-graph values attained since the
last HOLD reset. HOLD reset is activated by re-selecting
any function scale.
To select Peak HOLD: