- 8 -
5.4.3.
DMX CONTROL
5.4.3.1.
6-channel mode
Channel
Function
Value
Setting
(CH1)
NO
NO
NO
(CH2)
NO
NO
NO
(CH3)
Ignition
0~253
Ignition OFF
254~255
Start the ignition. When the DMX value on this channel is higher than 253, the flame
machine will ignite.
(CH4)
Opening time
0
Permanent fire
1~254
In steps of 10ms, to 2540ms
Opening time= DMX Value * 10ms
255
Permanent fire
(CH5)
NO
NO
NO
(CH6)
Mode
0~49
Pressure Relief Mode (Emergency Stop)
50~200
Compression Mode
201~255
Pressure Relief Mode (Emergency Stop)
5.4.3.2.
2-channel mode
Channel
Function
DMX Value
Setting
(CH1)
Ignition
0~253
No Fire
254~255
Start the ignition. When the DMX value on this channel is higher than 253, the flame
machine will ignite.
(CH2)
Mode
0~49
Pressure Relief Mode (Emergency Stop)
50~200
Compression Mode
201~255
Pressure Relief Mode (Emergency Stop)
6.
MAINTENANCE
1. To maintain the system in good performance and running status, it is recommended to running the device at least once per month.
2. In order to lubricate the pipeline and pump it is highly necessary to add 10-20ml castor oil per 10L canister.
It must not be pressurized without fuel in the tank, otherwise it will cause damage to the main board and
the pump.