background image

- 8 - 

5.4.3.

 

DMX CONTROL 

5.4.3.1.

 

6-channel mode  

Channel 

Function 

Value 

Setting 

(CH1) 

NO 

NO 

NO 

(CH2) 

NO 

NO 

NO 

(CH3) 

Ignition 

0~253 

Ignition OFF 

254~255 

Start the ignition. When the DMX value on this channel is higher than 253, the flame 

machine will ignite. 

(CH4) 

Opening time 

Permanent fire 

1~254 

In steps of 10ms, to 2540ms 

Opening time= DMX Value * 10ms 

255 

Permanent fire 

(CH5) 

NO 

NO 

NO 

(CH6) 

Mode 

0~49 

Pressure Relief Mode (Emergency Stop) 

50~200 

Compression Mode 

201~255 

Pressure Relief Mode (Emergency Stop) 

5.4.3.2.

 

2-channel mode  

Channel 

Function 

DMX Value 

Setting 

(CH1) 

Ignition 

0~253 

No Fire 

254~255 

Start the ignition. When the DMX value on this channel is higher than 253, the flame 

machine will ignite. 

(CH2) 

Mode 

0~49 

Pressure Relief Mode (Emergency Stop) 

50~200 

Compression Mode 

201~255 

Pressure Relief Mode (Emergency Stop) 

6.

MAINTENANCE

1. To maintain the system in good performance and running status, it is recommended to running the device at least once per month.

2. In order to lubricate the pipeline and pump it is highly necessary to add 10-20ml castor oil per 10L canister.

It must not be pressurized without fuel in the tank, otherwise it will cause damage to the main board and 

the pump.

Summary of Contents for TOPCAT HF-90

Page 1: ...HF 90 Machine Machine Machine Flame Flame Flame ...

Page 2: ......

Page 3: ...tructions from this manual Contact DJPOWER in case of doubts about the usage We assume that you your employees and others who use or come in contact with the machine are familiar with how the machine should be handled This includes proper use maintenance and repair of the machine as defined in this user guide This also means that employees are familiar with the use of machinery through training or...

Page 4: ...er cable communication DMX cable should well connected and ensure the command keep at firing OFF status And safety lock stay at test mode The operator responsible for the control of Wave flame machine must always have a clear view of the device so that he she can stop the show immediately when there is danger The main AC power switch should near operator So that operator can turn off the power of ...

Page 5: ... excellent atmosphere 2 2 Features Fast and high precision driving device and control system Fast and precise flame burst Rainproof design for the fuel nozzle thicken and anti rust metal structure durable in use Intelligent electronic control system Pressure no fluid monitoring Safety Failure warning Built in LCD control 3 pin and 5 pin DMX control Full set of SEETRONIC rainproof power connectors ...

Page 6: ...Flame Machine HF 90 comes with a power input cord terminated with a Lockable power connector on one end The other end is CN plug CN market etc EU plug EU market etc US plug US market etc If the power input cord that came with your product has no plug or if you need the change the plug use the table below to wire the new plug Connection Wire China Wire Europe Wire U S AC Live Brown Brown Black AC N...

Page 7: ...s the control panel functions use the four buttons located underneath the LCD display 5 3 On device Control Mode Operation 5 3 1 Programming Refer to the Menu Map to understand the menu options The menu map shows the main level and a variable number of programming levels for each option To go to the desired main level press MENU repeatedly until the option shows on the display This will take you t...

Page 8: ...ilts over 45 it stops running system will report E2 E3 Bat Err P 0 V 12 Machine stops running due to battery voltage higher than15V or lower than 10V for 5s contentiously Possible fault the battery is low E4 System Lock P 0 V 12 Safety lock located at TEST MODE E5 Relief Err P 0 V 12 Pressure relief error due to pipeline can t release pressure Possible fault pressure release valve failure pipeline...

Page 9: ...binet to avoid spilling ensure that the tube is placed in the fluid can tighten the container cap Please use the designated suitable fuels 4 Power and DMX cable connection 110V 220V main power supply See the item marked on the main label of the device 5 Switch ON the machine Please confirm safety lock located at TEST MODE before switch on the unit 6 Set DMX address The vertical flame machine can s...

Page 10: ...Stop 5 4 3 2 2 channel mode Channel Function DMX Value Setting CH1 Ignition 0 253 No Fire 254 255 Start the ignition When the DMX value on this channel is higher than 253 the flame machine will ignite CH2 Mode 0 49 Pressure Relief Mode Emergency Stop 50 200 Compression Mode 201 255 Pressure Relief Mode Emergency Stop 6 MAINTENANCE 1 To maintain the system in good performance and running status it ...

Page 11: ......

Page 12: ......

Reviews: