SPECIFICATION:

 

 
Temperature Control Range: -50 ~ 110 C 
Resolution at -9.9 to 99.9: 0.1 C 
Resolution at all other temperatures: 1 C 
Measurement Accuracy: 0.1 C 
Control Accuracy: 0.1 C 
Refresh Rate: 0.5 Seconds 
Input Power (DC): 12V 
Measuring Inputs: NTC (10K 0.5%) 
Waterproof Sensor: 0.5M 
Output: 1 Channel Relay Output, Capacity: 10A 
 
Power Consumption 
Static Current: <=35mA 
Current: <=65mA 
 
Environmental Requirements 
Temperature: -10 ~ 60 C 
Humidity: 20-85% 
 
Dimensions 
48mm x 40mm x 14mm 
 

 
Settings Chart 
Long press the “SET” button to activate the menu. 
 
Code Description Range Default Value 
P0 Heat C/H C 
P1 Backlash Set 0.1-15 2 
P2 Upper Limit 110 110 
P3 Lower Limit -50 -50 
P4 Correction -7.0 ~ 7.0 0 
P5 Delay Start Time 0-10 mins 0 
P6 High Temperature Alarm 0-110 OFF 
 
Long pr- will reset all values to their default 
 
 
 
 
Displaying the current temperature: 
The thermostat will display the current temperature in oC by default. When in any other mode 
making no input for approximately 5 seconds will cause the thermostat to return to this default 
display. 
 