29
Rotary Lobe Pumps - RZL-400 Series
800.789.1718
Maintenance
Pump Housing Disassembly - Double Mechanical Seal (continued)
6a.
If the rotors (38) will not come out freely, remove the stud bolt hex nuts (46) and then tap on the back of the inlet and outlet ports
with a soft hammer. Once the rotors (38) are loose, then push the casing (31) back towards the gear box and remove the rotors.
Summary of Contents for RZL-400
Page 6: ...6 Rotary Lobe Pumps RZL 400 Series 800 789 1718 Rotary Lobe Pump Composite Family of Curves...
Page 74: ...74 Rotary Lobe Pumps RZL 400 Series 800 789 1718 Certificates...
Page 75: ...75 Rotary Lobe Pumps RZL 400 Series 800 789 1718 Certificates...
Page 77: ...77 Rotary Lobe Pumps RZL 400 Series 800 789 1718 Notes...