
FloTech FT555PA/PW Automatic Truck Overfill System Tester
Page 14 10902PA Rev C FT555PA/PW Truck Tester
Max Therm Comps = # (English or Spanish)
Max 2-Wire Comps = # (English, French or German)
Press and release the GO button to toggle between 6 and 8
maximum number of compartments. Generally, the USA has a
maximum of 6 compartments signals per one socket and Canada or
European regions will have a maximum of 8. Once the correct
Maximum Compartments count is showing, press and release the
TEST SELECT button to move to the next SETUP screen.
AutoTest Optic/Therm (English or Spanish)
AutoTest 5-wire/2-wire (English, French or German)
Some regions may not have a need to test optic / 5-wire or
thermistor / 2-wire type systems as none are found in that region.
Example, trailers in California do not have Thermistor sockets so
there is no need to perform the Thermistor test. In this case the
Optic / 5-wire test would be enabled.
This screen will enable or disable the optic / 5-wire or
thermistor / 2-wire tests when performing an automatic test of the
trailer overfill system. This configuration is only for the automatic
testing mode. All four tests are available in the manual test
selection.
Max Therm Comps = 6
GO = Change
TEST SELECT = Next
Max 2-Wire Comps = 6
GO = Change
TEST SELECT = Next