Dixon BAYCO 5204 Maintenance & Operating Instructions Download Page 2

 

2

 

090092 Rev3 

These instructions are provided to ensure proper installation, operation and long service life 
of Bayco 5204K9 API Sight Glass Delete Kit.  This kit is intended for use with Bayco 5204 
API  valves  fitted  with  the  combination  fluid  level  and  flow  indicating  sight  glass.  This  kit 
includes a plate and gasket that are designed to seal the existing sight glass holes and to 
allow the API valve to operate without the sight glass. 

 

INSTALLATION INSTRUCTIONS  

 

CAUTION! 

THE  COMBINATION  FLUID  LEVEL  AND  FLOW  INDICATING 
SIGHT  GLASS  IS  EXPOSED  TO  DISCHARGE  (WET)  LINE 
PRESSURE,  REMOVAL  OF  THE  SIGHT  GLASS  WILL  RESULT  IN 
SPILLAGE  UNLESS  THE  INTERNAL  VALVE  IS  SECURED  SHUT 
AND  THE  DISCHARGE  (WET)  LINE  DRAINED  PRIOR  TO 
REMOVAL. 

 

 

Ensure  that  the  discharge  line  is  isolated  and  drained  before  attempting  to  remove  the 
combination fluid level and flow indicating sight glass.  
 
ATTENTION!   THE FLUID LEVEL AND FLOW INDICATORS ARE LOOSE PIECES AND 

ARE EASILY LOST. CARE SHOULD BE TAKEN DURING REMOVAL TO 
ENSURE  THAT  THESE  PARTS  ARE  SECURED  BEFORE  REMOVING 
THE SIGHT GLASS. 

 
Undo, remove and 

retain

 the six fasteners, flat washers and lock washers (note that only 

the  four  corner  fasteners  include  flat  washers,  two  additional  flat  washers  are  included  in 
your kit). 
 
Remove  the  sight  glass,  level  and  flow  indicators  and  o-ring.  These  may  be  retained  for 
future use, if serviceable. 
 
Ensure  that  the  sealing  surface  of  the  sight  glass  pad  on  the  5204API  valve  body  is  free 
from debris, scratching or anything that may result in leakage.  
 
Take the fasteners that you removed from the sight glass and the two flat washers included 
in  your  kit  and  ensure  that  you  have  six  screws,  flat  washers  and  lock  washers,  one  for 
each of the holes in the plate. 
 
Match the gasket up to the plate and line the plate and gasket up to the holes on the sight 
glass pad. Retain the plate and gasket with the fasteners.

 

 

DIXON BAYCO WARRANTY  

 

For Warranty Information, please refer to the inside back cover of the latest Dixon 
Catalogue.

 