Dixon Automatic Tool SKD-BN7030L Operation And Maintenance Manual Download Page 5

  

 

 

 

 

 

 

1

This tool should be grounded while in use to protect the operator from electric shock. NOTICE! To ensure the 

grounding result, the grounding conductor of the power cord must be well connected with the grounding terminal 
of power facility. This tool is equipped with grounding conductors. The Green (or Green and Yellow)conductor in 
the Power Cord is the grounding wire. Never connect Green (or Green and Yellow) to a live terminal. The 
grounding wires in this tool can not only earth the electric leakage safely, but also can eliminate ESD-the 
electrostatic that tool occurred while in use. 

2

The grounding is the most important task a user. Periodically, depends on the working condition and 

circumstance, for maintaining a good function the user has to check the grounding condition every 3~6 months 
by an electric meter and following simple steps; Set the Ohm meter to level R*100(Ohm). Touching 2 test rods 
(“

”) together and reset the meter to “0”. Using the Red (“

”) rod to touch the Grounding wire on the Plug 

of controller’s cord, and the Black(“

”) rod to the end of Bit Head. It stands for the grounding is normal if the 

meter is read as close as to “0”. For getting a normal indication on the meter while in testing, need to press the 
test rods firmly to the testing objects. 

3

The instrument QC of the tool is performed before the tool ex-factory. The grounding continuity test is conducted 

by input 26A voltage to the end of earth terminal, and subject to the resistance value lower than 0.3Ohm. 

 

 

 

 

 

1) Whenever changing a bit, make certain the Forward / Reverse Switch is in the “OFF “position and tool is 

unplugged. 

2) Do not allow chemicals such as acetone, benzene, thinner, trichloroethylene ketone, or other similar chemicals 

to come in contact with the screwdriver housing as damage will result. 

3) Do not drop or abuse the screwdriver. 
4) Do not adjust the torque setting higher than 8 on the torque scale. 
5) There should be a tool rest interval when cycles three seconds or longer. This tool is intended for a duty cycle of 

1.0 sec on, 3.0 sec off. 

6) Do not use this screwdriver for tightening wood screws. This is “Metal Assembly Screw Driver” 
7) Do not operate the Forward / Reverse Switch the motor is running. 
8) Whenever a tool is not being used, move the Forward / Reverse Switch to the “OFF” position and unplug the 

screwdriver. 

9) Don't touch For&Rev Switch during operating for keeping system from wrong judgment. 

10) 

Use cable for the external counter and I/O box is shield cable for avoidance of electrical interference 
Use Anti-interference lines.

 

Operations Cautions

 

Grounding Instructions

 

Summary of Contents for SKD-BN7030L

Page 1: ...30L SKD BN7030P DC TYPE Non Carbon Brush Electric Screwdrivers DIXON AUTOMATIC TOOL INC www dixonlighttools com DIXON AUTOMATIC TOOL INC 2300 23RD AVENUE ROCKFORD IL 61104 PHONE 815 226 3000 FAX 815 2...

Page 2: ...nenclosed Read all these instructions before placing tool in service or operation this tool and save these instructions It is the responsibility of the employer to place the information in this manual...

Page 3: ...ble for outdoor use Use of cord suitable for outdoor use reduces the risk of electric shock 3 Personal Safety a Stay alert watch what you are doing and use common sense when operating a power tool Do...

Page 4: ...ols sharp and clean properly maintained cutting tools with sharp cutting edges are less likely to bind and are easier to control g Use the power tools accessories and tool bits etc in accordance with...

Page 5: ...ter while in testing need to press the test rods firmly to the testing objects 3 Theinstrument QC of the tool is performed before the tool ex factory The grounding continuitytest is conducted by input...

Page 6: ...rque that you had set The tool will stop automatically To reset the tool by releasing the lever to the original position or releasing the bit From the screw head To return the screw set the changeover...

Page 7: ...service center 3 KILEWS is not responsible for customer modification of tools for applications on which KILEWS was not consulted 4 Repairs should be made only by authorized trained personnel Consult...

Page 8: ...screw 2 6 3 5 2 6 3 5 Weight g 836 Length mm 278 Model of Torque Fixing Ring KC 2C Standard tool KC 2S ESD tool Powercontroller SKP BE32HL BN6PIN SignalController KL SCBSN Model of Suspension Rack KH...

Page 9: ...of its mating part Use it as standard to obtain an appropriate clampingtorque 6 The Return torque method in which once clamped screw is returned with torque wrench or the like is available as one of...

Reviews: