background image

M095.x 

5 of 6 

 

22.

 

Center the Evaporator Fan Shroud Assembly in the back of the Cabinet so it rests on the bottom of 
the Tank. 

23.

 

With a drill, secure the Evaporator Fan Shroud Assembly with four (4) new Self Drilling Screws 
(800,304,18x.x1).  See “A” in Figure 6. 

 

 

 

 

24.

 

Carefully move the Evaporator clockwise to the surfaces of the new Evaporator Fan Shroud. 

25.

 

Align the holes of the Evaporator to the holes of the Evaporator Fan Shroud Brackets. 

26.

 

Secure with four (4) new Screws (800,304,31x.x1) that were removed in Step #8. 

27.

 

Carefully insert the Cold Control Sensor in the slot in the shroud.  See Figure 8. 

28.

 

Align the male fan connectors to the female fan connectors of the Main Power Harness shown in 
Figure 7.  When connecting, align ribbed wires with ribbed wires, smooth with smooth. 

 

     

 

 
 

 

 

29.

 

 Lay the new Top Evaporator Cover (609,050,84x.x3) on a flat surface.  Clean the area shown in 
Figure 9 with a solvent to remove any dirt and oil. 

Figure 6

 

Figure 8

 

Figure 7

 

Main Power  

Harness 

Note: 

Ribbed Wire

A

A

A

A

Slot

Reviews: