Frontal protection: IP65 with frontal gasket RG-C (optional).
Connections: Screw terminal block
≤
2,5 mm
2
heat-resistant wiring.
Power supply: 12Vac/dc (opt.24Vac/dc), ±10%
Power absorption: 5VA max.
Inputs: 3 NTC or PTC probes
Relay outputs
compressor1:
SPST relay 8(3) A, 250Vac or
compressor
2: relay SPDT 8(3) A, 250Vac
defrost: relay SPDT 8(3) A, 250Vac
fans: relay SPST 8(3) A, 250Vac
Other output: Alarm buzzer
Kind of action: 1B.; Pollution grade: normal; Software class: A.
Data storing: on the non-volatile memory (EEPROM).
Operating temperature: 0÷60 °C.
Storage temperature: -25÷60 °C.
Relative humidity: 20
÷
85% (no condensing)
Measuring and regulation range: -40÷110°C (-58÷230°F)
Resolution: 0,1 °C or 1°C or 1 °F (selectable).
Accuracy (ambient temp. 25°C): range -40÷50°C (-40÷122°F): ±0,5 °C ±1 digit
15.
WIRING CONNECTIONS
N.C.
Line
8(3)A250V
~
8(3)
A
8(
3)A
Max
16A
Comp1
Def
Fan
R
oom
1
1
2
3
4
5
Co
nf
ig.
2
Co
nfi
g.
1
N.C.
8(3)A
7
8
9
Line
C omp2
Ho
t K
ey
13 14 15 1 6 17 18 19
20 21
22 23
Supply
12V
=
De
f.
Ro
om
2
16.
DEFAULT SETTING VALUES
Label Nome
Range
Default level
REGULATION
Set1
Set point 1
LS1÷US1
-5
Pr1
Set2
Set point 2
LS2÷US2
3
Pr1
Hy1
Differential 1
0,1÷25,5 °C / 1÷45°F
2.0
Pr1
Hy2
Differential 2
0,1÷25,5 °C / 1÷45°F
2.0
Pr1
REGULATION – SECTION 1
LS1
Minimum set point1 limit
-50,0°C÷SET1 / -58°F÷SET1
-50.0
Pr2
US1
Maximum set point1 limit
SET1 ÷ 150°C / SET1 ÷ 302°F 110 Pr2
odS1 Outputs activation delay of sect. 1 at start up 0÷255 min.
0
Pr2
Ac1
Anti-short cycle delay for compressor1 0÷30
min.
1
Pr1
con1 Compressor1 ON time with faulty probe1
0÷255 min.
15
Pr2
coF1 Compressor1 OFF time with faulty probe1
0÷255 min.
15
Pr2
cH1
Kind of action for section 1
cL / Ht
cL
Pr2
REGULATION – SECTION 2
LS2
Minimum set point2 limit
-50,0°C÷SET2 / -58°F÷SET2
-50.0
Pr2
US2
Maximum set point2 limit
SET2 ÷ 150°C / SET2 ÷ 302°F 110 Pr2
odS2 Outputs activation delay of sect. 2 at start up 0÷255 min.
0
Pr2
Ac2
Anti-short cycle delay for compressor2 0÷30
min.
1
Pr1
con2 Compressor2 ON time with faulty probe2
0÷255 min.
15
Pr2
coF2 Compressor2 OFF time with faulty probe2
0÷255 min.
15
Pr2
cH2
Kind of action for section 2
cL / Ht
cL
Pr2
DISPLAY
cF
Temperature measurement unit
°C / °F
°C
Pr2
rES
Resolution (for °C
in ÷ de
dE
Pr1
Lod1 Bottom display visualization
P1 ÷ P4
P1
Pr2
Lod2 Upper display visualization
P1 ÷ P4
P2
Pr2
DEFROST
dFS
Relation between defrosts
ind; StS; Sti, SE
ind
Pr2
tdF1
Kind of defrost section 1
rE, in
rE
Pr2
EdF1 Defrost mode, section 1
In, Sd,RTC
in
Pr2
SdF1 Set point for Smart Defrost section 1
-30 ÷ +30°C / -22÷+86°F
0
Pr2
dtE1
End defrost temperature section 1
-50,0÷110°C/ -58÷230°F
6.0
Pr2
idF1
Interval between defrosts, section 1
1÷120ore
6
Pr1
MdF1 Maximum duration of defrost, section 1
0÷255 min.
20
Pr1
tPF1
Pre-defrost compressor on time
0÷30 min.
0
Pr2
Fdt1
Dripping time section 1. 1
0÷60 min.
0
Pr2
dPo1 Defrost at power on section . 1
n ÷ y
n
Pr2
EdF2 Defrost mode, section 2:
In, Sd, RTC
in
Pr2
idF2
Interval between defrosts, section 2
1÷120ore
8
Pr1
MdF2 (Maximum) duration of defrost, section 2
0÷255 min.
20
Pr1
dFd
Display during defrost
rt, it, SEt, dEF, dEG
it
Pr2
dAd
Defrost display time out
0÷255 min.
20
Pr2
dSd
Defrost delay
0÷255 min.
0
Pr2
FANS
FnC1 Fans operating mode, section 1
C-n, C-y, O-n, O-y
O-n
Pr2
Fnd1 Fans delay after defrost, section 1
0÷255 min.
10
Pr2
FSt1
Fans stop temperature, section 1
-50,0÷110°C/ -58÷230°F
2.0
Pr2
FAP1 Probe for fans
P1÷P3
P3
Pr2
Label Nome
Range
Default level
ALARM
ALc1 Temperature alarms configuration, section 1 rE / Ab
Ab
Pr2
ALu1 Maximum alarm, section 1
-50,0÷150°C/ -58÷302°F
110
Pr1
ALL1 Minimum alarm, section 1
-50,0÷150°C/ -58÷302°F
-50.0
Pr1
ALd1 Temperature alarm delay, section 1
0÷255 min.
15
Pr2
dAo1 Delay of temp. alarm at start-up, section 1
0 ÷ 23h 50 min.
1.3
Pr2
ALc2 Temp. alarms configuration, section 2
re ÷ Ab
Ab
Pr2
ALu2 Maximum alarm, section 2
-50,0÷150°C/ -58÷302°F
110
Pr1
ALL2 Minimum alarm, section 2
-50,0÷150°C/ -58÷302°F
-50.0
Pr1
ALd2 Temperature alarm delay, section 2
0÷255 min.
15
Pr2
dAo2 Delay of temp. alarm at start-up, section 2
0 ÷ 23h 50 min.
1.3
Pr2
AFH
Temperature alarm and fan differential
0,1÷25,5 °C / 1÷45°F
1.0
Pr2
EdA
Alarm delay at the end of defrost
0÷255 min.
20
Pr2
dot
Delay of temp. alarm after closing the door
0÷255 min.
20
Pr2
doA
Open door alarm delay
0÷254 min., nu
15
Pr2
Pbc
Kind of probe
PTC/ntc
ntc
Pr2
ANALOGUE
INPUTS
oFS1 Thermostat1 probe calibration
-12,0÷12,0°C / -21÷21°F
0.0
Pr2
oFS2 Thermostat2 probe calibration
-12,0÷12,0°C / -21÷21°F
0.0
Pr2
oFS3 Evaporator probe calibration
-12,0÷12,0°C / -21÷21°F
0.0
Pr2
P2P
Thermostat2 probe presence
n / y
Y Pr2
P3P
Evaporator probe presence
n ÷ y
Y
Pr2
DIGITAL
INPUTS
i1P
Digital input 1 polarity
cL÷OP
cL
Pr2
i1F
Digital input 1 operating mode
MP1; MP2, MP; EA1; EA2;
EAL; bA1; bA2; , bAL; dF1;
dF2; dEF; oF1; oF2; oFF; ES
MP1 Pr2
i2P
Digital input 2 polarity
cL÷OP
cL
Pr2
i2F
Digital input 2 operating mode
MP1; MP2, MP; EA1; EA2;
EAL; bA1; bA2; , bAL; dF1;
dF2; dEF; oF1; oF2; oFF; ES
MP2 Pr2
odc1 Comp. and fan status when open door, sect
1
no, Fan, CPr, F_C
FAn Pr2
rrd1
Outputs restart after door open alarm, sect. 1 n, y
Y
Pr2
did1 Time interval delay for digital input alarm,
sect. 1
0÷255 min.
15 Pr2
odc2 Comp. status when open door, section 2:
no, Fan, CPr, F_C
no
Pr2
rrd2
Outputs restart after door open alarm, sect. 2 n, y
Y
Pr2
did2 Time interval delay for digital input alarm,
sect. 2
0÷255 min.
5 Pr2
OTHER
HES1 Temp. increase during the Energy Saving
cycle, sect. 1
-30÷30°C / -54÷54°F
0
Pr2
HES2 Temp. increase during the Energy Saving
cycle, section 2
-30÷30°C / -54÷54°F
0
Pr2
Adr1
RS485 serial address, section 1
1÷247
1
Pr2
Adr2
RS485 serial address, section 2
1÷247
1
Pr2
dP1
Thermostat 1 probe value
- - -
- - -
Pr1
dP2
Thermostat 2 probe value
- - -
- - -
Pr1
dP3
Evaporator probe value
- - -
- - -
Pr1
onF
Stand-by function
y, n
- - -
Pr2
rEL
Release software
---
- - -
Pr2
Ptb
Parameter table
- - -
- - -
Pr2
Pr2
Access to the protected parameter list
- - -
Pr1
Dixell S.p.A.
Via dell’Industria, 27 - 32010 Z.I Pieve d’Alpago (BL) ITALY
tel. +39 - 0437 - 98 33 - fax +39 - 0437 - 98 93 13 –
E-mail:[email protected] -
http://www.dixell.com