Controller 

DIXELL-XR20C   

Parameter setting code

D20-001M 

Parameter setting sheet for 

Entree R

efrigerator 

CODE 

PARAMETER 

SET 

Set 

Main Set point 

34 

Hy 

Differential(hysteresis) 

LS 

Lower limit of main set point 

28 

US 

Upper limit of main set point 

50 

Ot 

Offset 

-1 

P2P 

Evaporator probe presence 

OE 

Evaporator probe calibration 

Ods 

Outputs delay at start up 

AC 

Minimum time interval between the disactivation and successive activation 
on compressor  

CCt 

Continuous cycle duration 

Con 

Compressor on-time during by probe failure 

10 

COF 

Compressor off-time during by probe failure 

10 

CF 

Unit of measure 

℉ 

rES 

Resolution 

dE 

Lod 

Probe displayed 

P1 

Edf 

Defrost termination setting 

Pb 

dtE 

Defrost-end temperature 

41 

IdF 

Time interval between defrost cycle 

MdF 

Max defrost cycle time 

20 

dFd 

Displaying during defrost 

SEt 

dAF 

Defrost delay after fast freezing 

dAd 

Real temperature display delay at defrost end 

30 

ALC 

Temperature alarms configuration 

rE 

ALU 

Max temperature alarm differential 

50 

ALL 

Minimum temperature alarm differential 

20 

ALd 

Minimum or minimum temperature alarm delay 

60 

dAO 

Delay of temperature alarm at start up 

i1P 

Digital input polarity 

CL 

i1F 

Digital input configuration  

dor 

did 

Digital input alarm delay 

15 

NPS 

Number of activation of pressure switch 

15 

Odc 

Compressor and fan status when open door 

no 

Pbc 

Kind of probe 

ntc 

dP1 

Room probe display 

-- 

dP2 

Evaporator probe display 

-- 

rEL 

Software release 

-- 

Ptb 

Map code 

-- 