ขอมูลทางเทคนิค

 

Housing: 

Self extinguishing ABS. 

Case: 

Front panel 32x74 mm, depth 60mm (“C” format);  

Mounting :

 “C” format panel mounting in a 29x71 mm panel 

cut-out  

Protection: 

IP65.

 

Frontal protection:

 IP65 with frontal gasket mod RG-C 

model. 

Connections: 

Removable terminal block 12 and 14 ways;  

Power supply: 

12Vac/dc 

±

 10%, 24Vac/dc 

±

 10%, 50-60Hz.  

Power absorption: 

5VA max.

 

Display:

 3 digits red led and 4 digit orange led.  

 

Inputs:

 2 NTC probes, or 2 PTC probes and 2 4..20mA 

transducer. 

Digital inputs

: 5 free voltage 

Relay outputs: 

5 relay SPST 5(3)A, 250Vac 

Open collector:

 alarm output: 12V, 40mA. 

Analogue output:

 4..20mA for fan control, trigger for fan 

control 

Serial output:

 TTL standard 

Communication protocol:

 

ModBus – RTU

 

Data storing:

 on the non-volatile memory (EEPROM). 

Kind of action: 

1B; 

Pollution grade: 

normal; 

Software 

class: 

A. 

Operating temperature: 

0÷60 °C.; 

Storage temperature: 

-

25÷60 °C.  

Relative humidity:

 20

÷

85% (no condensing)  

Measuring range: NTC probe: 

-40÷110°C. 

Resolution: 

0, 1 °C or 1°C; 

Accuracy (ambient temp. 25°C)

:  

±0, 7 °C ±1 digit

 

 

18. 

สัญญาณเตือน

 

โดยปกติสัญญาณเตือนสามารถสงสัญญาณออกไดตามตอไปนี้

 

1.     

ไปสั่งงานทางเอาทพุทของสัญญาณเตือน

 0-12 V 

2.      

สงสัญญาณเตือนแบบมีเสียง

 

3.      

ขอความแสดง

 

  4.      

เก็บบันทึกสัญญาณเตือนไวในตัวคอนโทรล

 

18.1  

ชนิดของสัญญาณเตือน

 

และการจัดการ

 

18.1.1  A12: 

สัญญาณเตือนการปรับตั้งคา

 

คอนโทรลจะตรวจสอบการตั้งคาอีกครั้งหลังจากมีการ

เปลี่ยนแปลงตามตอไปนี้

 

OA1-OA5 

  

การปรับคาเอาทพุท

 1-5 

P2P 

การใชงานหัววัดที่

CtyP

ชนิดของคอมเพรสเซอร

 

dSEP

 

การใชงานคา

 Set Point 

แบบ

 Dynamic 

AOP 

หัววัดสําหรับสัญญาณอนาล็อกเอาทพุท

 

tOP 

 

หัววัดสําหรับ

 Triac 

เอาทพุท

 

เมื่อพารามิเตอรเหลานี้มีการตั้งคาที่ผิดไป

 

สัญญาณเตือนจะ

แสดง

 

โดยขอความ

 A12 

จะแสดงในบรรทัดบน

 

สวนบรรทัดลางจะ

แสดงชนิดของพารามิเตอรที่ตั้งคาผิด

 

โดยจะแสดงตามคาตาราง

ขางลาง

 

 

ขอความ

 

ความหมาย

 

ขอความทํา

 

nLod 

จํานวนโหลดที่ตั้งสูง

เกินกวาที่ตัว

คอนโทรลมี

 

ตรวจสอบพารามิเตอร

 

oAi 

ซึ่งจะตองมีคาเทากับ

หรือนอยกวาจํานวนรีเลย

ของคอนโทรล

 

cStP 

การตั้งคาของโหลด

(

สเต็ป

ผิด

 

รีเลย

 oA(i) 

ถูกตั้งเปน

คอมเพรสเซอร

 

โดยที่รีเลย

กอนหนานั้น

 oA(i-1)  

ไมไดตั้งเปน

คอมเพรสเซอร

  oA1=StP 

AOP2 

หัววัดที่

 2 

ไมสามารถ

ใชไดกับสัญญาณ

เอาทพุท

 4..20 mA  

หัววัดที่

 2 

ไมถูกเรียกใช

งาน

 P2P=no 

ทําการ

เรียกใชงานหัววัดที่

 2 

P2P=yes 

หัววัดที่

ถูกใชไปในการ

ควบคุมอุณหภูมิของเครื่อง

คอมเพรสเซอรแบบสกรู

  

ตรวจสอบ

 CtyP 

และตั้งคา

อื่นที่ไมใช

 Scr 

dSP2 

หัววัดที่

 2 

ไมสามารถ

เรียกใชงานไดสําหรับ

การตั้งคา

 Set Point 

แบบ

 Dynamic 

หัววัดที่

 2 

ไมถูกเรียกใช

งาน

 P2P=no 

ทําการ

เรียกใชงานหัววัดที่

 2 

P2P=yes 

หัววัดที่

ถูกใชไปในการ

ควบคุมอุณหภูมิของเครื่อง

คอมเพรสเซอรแบบสกรู

 

ตรวจสอบ

 CtyP 

และตั้งคา

อื่นที่ไมใช

 Scr 

FAP2 

หัววัดที่

ไมสามารถ

เรียกใชงานไดสําหรับ

การควบคุมพัดลม

 

หัววัดที่

 2 

ไมถูกเรียกใช

งาน

 P2P = no 

ทําการ

เรียกใชงานหัววัดที่

 2 P2P 

= yES 

หัววัดที่

ถูกใชไปในการ

ควบคุมอุณหภูมิของเครื่อง

Summary of Contents for XC650C

Page 1: ...Electronic Controller for Compressor Racks XC650C Instructions Manual...

Page 2: ...2 6 7 3 6 8 6 8 1 6 8 2 6 9 6 9 1 6 10 HOT KEY 7 10 1 hot key Upload 7 10 2 Hot Key Download 7 11 7 11 1 7 11 2 7 12 7 12 1 7 12 2 8 12 3 9 12 4 10 12 5 10 12 6 10 12 7 10 12 8 11 12 9 Dynamic set poi...

Page 3: ...ndensing Multistage Neutron Zone Proportional Zone LP HP LP HP 2 HOT KEY XJ500 Monitoring 3 1 2 6 12 3 1 R404 1 Set n 3 2 Pr2 3 2 1 3 FtyP 4 SET 5 o n r22 R22 r404 R404 507 R507 134 134 r717 6 SET SET...

Page 4: ...Set n 3 2 Pr2 3 2 1 3 PA04 4 mA 4 SET 5 1 6 SET PA20 20 mA 7 1 8 SET 2 FA04 FA20 3 3 PA04 PA20 FA04 FA20 1 Set n 3 2 Pr2 3 2 1 3 o rELP 4 SET 5 Abs SET SET o 30 4 4 1 ICONS 1 Icon 2 1 2 Icon 4 2 SET...

Page 5: ...5 5 1 HZ 5 2 HZ 5 1 5 Set Point 5 1 Set Point Set Point Set Point 1 SET 2 SEtC 3 Set Point SET 4 SEtF SET 30 5 2 Set Point Set Point FtyP dEU 1 FtyP 3 1 2 dEU 3 Set Point LSE HSE 1 SET 2 2 SEtC 3 o n...

Page 6: ...n SET 5 2 3 NOTE Pr2 Pr1 SET n Pr1 6 3 1 2 o n 3 SET 4 SET SET o 15 NOTE 7 7 1 1 CLOCK 3 2 LED StA ON OFF LED 3 o n 4 SET o n ON OFF 5 SET CLOCK 30 7 2 LED 2 Hz 7 3 8 8 1 1 CLOCK 2 LED HUr 3 o CLOCK 3...

Page 7: ...Hot Key NOTE Err o UPLOAD Hot key 10 2 Hot Key Download 1 2 Hot Key 5 3 doL End 4 10 5 Hot Key NOTE Err Hot key UPLOAD DOWNLOAD E2 Hot Key 11 11 1 1 o n 3 2 POF HACCP 11 2 o n 3 POn 12 12 1 oA1 oA2 o...

Page 8: ...oA1 CPr oA2 StP oA3 Fan oA4 Fan oA5 Fan CtyP Homogeneous dPo Neutral Zone StP Neutral Zone Proportional Band Scr StPP Homogeneous oP cL PC1 PC5 1 5 CtyP dPo 1 255 3 10 20 40 PC1 10 PC2 20 PC3 40 FtyP...

Page 9: ...0 3100KPA PA04 CAL 1 12 0 12 0bar 12 0 12 0 C 20 20 PSI F 12 2 2 2 P2P 2 no 2 yES 2 Pbc2 2 Cur 4 20mA ntc NTC Ptc PTC FA04 2 Pbc2 Cur 4mA 0 31bar 0 450 PSI 0 3100KPA 1 PP11 0 5 12 0 PA 0 5 0 5 1 PA20...

Page 10: ...0 10 5 00 bar 0 5 30 C 1 80 PSI 1 50 F Set Point set Pbd 2 set Pbd 2 dEU ESC 20 20 bar 50 50 C Set Point onon 0 255 oFon 0 255 Note onon oFon don 2 0 99 5 res10s doF 2 0 99 5 res10s donF 0 99 5 res10...

Page 11: ...et Point set LAF LA2 HAF dEU Set Point set HAF HA2 AFd 0 255 PnF Low Pressure Switch 0 15 0 Low Pressure Switch PnF PiF 17 Pressure switch PiF Pressure Switch 1 15 PEn High Pressure Switch FPr 0 12 9...

Page 12: ...neutral zone Pbd Set Point set Pbd 2 set Pbd 2 SET Pbd 2 don doF onon oFon donF neutral zone homogeneous 1 onon oFon donF Dead band 1 oA1 cPr oA2 cPr oA3 cPr oA4 nu oA5 nu CtyP SPo homogenous Rty db d...

Page 13: ...4 Set Pbd 4 don doF ALL LOADS ON ALL LOADS OFF doF doF 14 29x71 IP65 mod RG C 0 60 C 15 1 0 mm2 14 12 Note 17 19 Common 1 15 2 16 21 22 Common 3 18 4 20 5 TTL RS485 4 2 0 2 mm2 HP 10 Vdc Open Collecto...

Page 14: ...lay SPST 5 3 A 250Vac Open collector alarm output 12V 40mA Analogue output 4 20mA for fan control trigger for fan control Serial output TTL standard Communication protocol ModBus RTU Data storing on t...

Page 15: ...ut HP SEP Low pressure switch polarity SEP cL SEP oP HPP High pressure switch polarity SEP cL SEP oP Pen PEi n 3 PnF PiF n 3 18 1 3 EA1 EA5 10 11 12 13 14 ID5 ALIP ALIP cL ALIP oP ALMr ALMr no ALMr yE...

Page 16: ...a Restart n 3 b E0H PEn PEi PEn PEi Restart n 3 P1 1 1 SPr PoPr P2 2 2 FPr EA1 EA2 EA3 EA4 EA5 NOTE 1 1 ALMr ALMr no ALMr yES n 3 LA SET_C LAL Set_C LAL differential differential 0 3bar 1 C LA2 Conde...

Page 17: ...AL Set_C HAL differential differential 0 3bar 1 C HA2 Condensing SET_F HAL Set_F HAL differential differential 0 3bar 1 C A5 A14 SEr par 8 19 Wiring connections Line Line LOAD1 LOAD2 LOAD4 LOAD3 LOAD5...

Page 18: ...134 717 rtY db db db db Pr2 db Pb StY yES yES yES yES Pr2 no YES rot yES yES yES yES Pr2 no YES Pbc Cur Cur Cur Cur Pr2 1 cur Ptc ntc PA04 0 5 7 0 5 7 Pr2 4mA 0 0 bar o 0 PSI PA20 PA20 12 0 174 12 0...

Page 19: ...Pr2 0 255 sec LSE 40 40 0 3 5 Pr2 Set Point PA04 HSE HSE 10 50 7 2 100 Pr2 Set Point LSE PA20 Pb 4 8 2 0 24 Pr2 Proportional band neutral zone 0 1 10 0 bar 30 0 C 80 PSI 50 F ESF 0 0 0 0 Pr2 20 0 bar...

Page 20: ...ar 50 0 C 300 PSI 90 F AOP nP nP nP nP Pr2 nP 0 P1 1 P2 2 LAO 0 0 0 0 Pr2 AOC Pb 0 0 51 0 BAR 50 0 150 0 C 0 750 PSI 58 302 F UAO 1 1 1 1 Pr2 AOC Pb 0 0 51 0 BAR 50 0 150 0 C 0 750 PSI 58 302 F AOM 4...

Reviews: