background image

Page 5 of 17 

SECTION 3 – SETUP / INSTALLATION 

3.1 To Setup or Install Safely 

 

 

Do not place unit near flammables or combustible surfaces. 

 

Refer to SECTION 2:  Specifications, to know the electrical requirements of the unit you are 
installing and ensure adequate input power that is properly sized, rated, and protected. 

 

This unit must be grounded for safe operation. 

3.2 Un-Packaging 

1.

 

Immediately upon receiving the unit, carefully examine the carton for damage during transit.  

2.

 

Remove packing material. 

3.

 

Avoid tipping or inverting during handling. 

4.

 

The item serial number, model, and electrical ratings are listed on the nameplate.  Record this information in the 
Maintenance Record provided on page 10, or your own preventative maintenance system. 

3.3 Selecting a Location 

 

Choose a location where the unit will be used, near the operator. 

 

Choose a location sufficiently close to a grounded power source. 

3.4 Installation 

 

Electrical Connection: 

o

 

This unit requires 3-phase (230/460/575V) direct connection.  

o

 

See APPENDIX 1:  Electrical Diagram for wiring instructions.   

o

 

Have a certified electrician install electrical connection according to local regulations. 

o

 

All three power leads must be connected to L1, L2 and L3 on the contactor.

 

o

 

This unit must be grounded for safe operation. 

o

 

If on start-up the downdraft table seems to be lacking performance or the table sounds very loud, the 
motor is most likely running in the reverse direction.  Reversing leads L1 and L3 will reverse motor rotation in 
the right direction. 

 

o

 

Correct direction of BLOWER WHEEL ROTATION = CLOCKWISE

 

 

Compressed Air: 

o

 

Supply 80-90 PSI of CLEAN, DRY, compressed air to the bulkhead bushing on the side of the unit.

 

o

 

The air tank in the downdraft table is fabricated to allow a maximum of 90 PSI, DO NOT attempt supplying 
air pressure greater than 90 PSI without a properly installed pressure regulator.

 

o

 

Moisture in airline can damage filter(s); use an air dryer if required. 

 

Special Installation steps for table options: 

o

 

Plasma Cutting Packages & Kits 

o

 

Spray Painting Packages & Kits 

3.5 Preparing Unit for Operation 

 

Remove all packaging and shipping protection before use, in accordance with SECTION 3.2:  Un-Packaging 

 

Select a location appropriate for use that complies with all safety instructions contained herein, and SECTION 3.3:  
Selecting a Location. 

 

Confirm installation of correct input power source, compressed air, and any special installation requirements, in 
accordance with SECTION 3.3:  Installation.  Look at the manufacturer’s label located on the exterior of the unit and 
ensure the source is correctly sized in terms of Voltage and Amperes.  

 

Prior to use in your application, turn the unit ON, and perform a function test.  To do so: 

o

 

Turn switch to ON position 

o

 

LOOK:  Is the unit level, stable, and that nothing is obstructing the extraction path. 

o

 

LISTEN:  Does the motor and suction sound smooth and within expected volumes. 

o

 

FEEL:  Place your hand on top of the unit and sense for unexpected vibration.  Place you hand in front of 
the intake surface and sense for expected level(s) of suction. 

 

 Inform all potential users of this equipment where they may find and review this manual. 

Summary of Contents for DD-3X4

Page 1: ...es DD 4X4 DD 4X6 DD 4X8 DD 5X10 Multi Workstation Tables READ AND SAVE THESE INSTRUCTIONS Visit our Website for more information on this product www diversitech ca 2500 Alphonse Gariepy Montreal Quebe...

Page 2: ...ation 5 3 5 Preparing Unit for Operation 5 SECTION 4 OPERATION 6 4 1 To Operate Safely 6 4 2 Controls 6 4 3 Pre Use Checklist 6 4 4 Principles of Operation 6 4 5 Reverse Pulse Filter Cleaning System 7...

Page 3: ...tered air either indoors or outdoors Before use inspect the unit for damage and verify it is working properly Only qualified persons should install operate maintain or repair this unit Do not modify o...

Page 4: ...Page 2 of 17 SECTION 2 SPECIFICATIONS 2 1 Model Configurations Description Open Works surface Side Back Walls Clean Air Workstation DD 3X4 DD 3X6 DD 3X8 DD 4X4 DD 4X6 DD 4X8 DD 5X10...

Page 5: ...Filter Part Filter Filter Filter Qty Type Number Size Area Efficiency Filters sq ft Required DD 3X4 Nanofiber S 3X4 0024 16 w flange 140 99 99 0 5 micron 2 DD 3X6 Nanofiber S 3X6 0024 16 w flange 140...

Page 6: ...48 36 14 6 x 2 DD 4X6 10 x 2 73 68 5 49 72 48 36 14 6 x 2 DD 4X8 10 x 2 97 68 5 49 96 48 36 14 6 x 2 DD 5X10 10 x 2 121 68 5 31 120 30 36 34 12 x 2 DD 3X4 EO 10 x 2 49 68 5 49 48 48 36 14 12 DD 3X6 E...

Page 7: ...or rotation in the right direction o Correct direction of BLOWER WHEEL ROTATION CLOCKWISE Compressed Air o Supply 80 90 PSI of CLEAN DRY compressed air to the bulkhead bushing on the side of the unit...

Page 8: ...e unit level stable and that nothing is obstructing the extraction path o LISTEN Does the motor and suction sound smooth and within expected volumes o FEEL Place your hand on top of the unit and sense...

Page 9: ...above the drawer prevent the dust from re entering the cabinet when the machine is turned on Neglecting to pulse the filter regularly will reduce filter life Factory Setting DIP SWITCH FACTORY SETTIN...

Page 10: ...ing filter inspection The input power to this unit is high voltage and touching any live electrical parts can cause fatal shocks or severe burns Do not touch live electrical parts Keep away from all m...

Page 11: ...Operating Hours Inspect Clean Cabinet Remove and wipe down dust drawer baffle trays and metal mesh prefilters depositing accumulated particulate in appropriate waste container Refer to local regulati...

Page 12: ...nge when pulsed regularly is 6 18 months As part of routine maintenance it is important to visually inspect the filter Replace the filter if you see 1 Overloading or accumulation of particles 2 Rips t...

Page 13: ...Page 11 of 17 5 5 Troubleshooting Procedure...

Page 14: ...er ELECTRIC SHOCK HAZARD Disconnect power before performing any maintenance on unit including filter inspection The input power to this unit is high voltage and touching any live electrical parts can...

Page 15: ...photocopied or otherwise reproduced as needed for management of maintenance records MANUFACTURER DIVERSITECH INC MODEL NO FRED SERIAL NO SERVICE LOCATION CONTROL NO Date Description of Service Servic...

Page 16: ...10 0HP Aluminum Blower Wheel backward inclined S WHEL 0012 15 0HP Aluminum Blower Wheel backward inclined S 184T 050T2 5 0HP TEFC MOTOR 230 3 60 S 184T 050T4 5 0HP TEFC MOTOR 460 3 60 S 184T 050T5 5...

Page 17: ...14 Hinged left right side walls fixed back 4 steel frame w clear lexan insert A X SMW 01 Side walls middle seperator powder coated mild steel A X SMW 11 Side walls middle seperator 4 steel frame with...

Page 18: ...Page 16 of 17 NOTES...

Page 19: ...Page 17 of 17 NOTES...

Page 20: ...reight claims for obvious or concealed damages which developed in transit from Montreal to your location or when drop shipped RETURN MATERIAL POLICY Prior to the return of material for whatever reason...

Reviews: