background image

ASURITY

TM

CONDENSATE MANAGEMENT

PAGE

 

2

 

INTRODUCTION

SAFETY INFORMATION 

Please read, understand, and follow all safety instructions. Failure to follow 

instructions may result in property damage, serious injury, or death.

 

DANGER

    

ALWAYS

 disconnect power prior to moving, adjusting, or servicing 

pump or attached systems.

 

DO NOT 

use this pump in the presence of 

spraying or standing water. Failure to do so could result in a fatal electric 

shock

.

WARNING: FIRE AND EXPLOSION HAZARD

  

DO NOT

 use this pump to move flammable or explosive liquids.

 

DO NOT

 

use this pump in explosive or flammable environments.

 

 Carbon monoxide hazard. Ensure that pump is mounted away from heat   

  exchanger or wiring. If you are unsure of any items in this manual, please  

 consult a professional and 

DO NOT

 

attempt to install this product.

CALIFORNIA PROPOSITION 65

  

 This product may contain chemicals known to the state of California to 

cause cancer, birth defects, or other reproductive harm. Wash hands 

after handling this product. 

CAUTION: FLOOD RISK

  

 Personal injury or property damage can result from an inoperative 

pump. If a flood has occurred, 

DO NOT

 walk in wet area until all power 

has been turned off. Check with local electric company or a qualified 

electrician before disconnecting any electrical service prior to pump 

removal. 

WARNING

 

    

Supply voltage and frequency must match what is shown on pump 

nameplate. Source voltages lower than the rated supply can reduce 

performance and cause pump to overheat. 

    

Pump must be level and should be mounted to or placed on a solid 

surface or floor. 

  

 DO NOT

 cover pump air vents. Pump is air cooled. 

DO NOT

 cover 

vent holes located on top or sides of the pump housing. Pump may be 

operated continuously as long as air vents are not covered.

 

 Pump should be stored indoors. The chosen location should be clean    

  and dry.

  This appliance is not intended for use by persons (including children) 

      with reduced physical, sensory or mental capabilities, or lack of   

 

  experience and knowledge, unless they have been given supervision or    

Summary of Contents for Asurity ULTRACP-22

Page 1: ...Installation Instructions Standard Applications Models ULTRACP 22 ULTRACP 22 230 ULTRACP 22T ULTRACP 22T 230 Condensate Pump Ultra...

Page 2: ...r birth defects or other reproductive harm Wash hands after handling this product CAUTION FLOOD RISK Personal injury or property damage can result from an inoperative pump If a flood has occurred DO N...

Page 3: ...nd pumps water to a remote location for disposal When tank is sufficiently empty pump automatically switches off Pump is capable of lifting water up to 22 ft and is equipped with a check valve that pr...

Page 4: ...1 B Inlet Hole Covers 3 C Wires with Pre crimped Connectors 1 A ULTRACP 22 ULTRACP 22 230 Rated Voltage 120 Volts 60Hz 230 Volts 60 Hz Rated Current Draw 1 9 Amps 1 0 Amps Head Height 22 ft maximum 22...

Page 5: ...TING OPTIONS 1A PLACE ON FLOOR Determine condensate pump location 1B ATTACH TO WALL Attach condensate pump with screws 8 in between mounting tabs OPTION REVERSE TOP IF NECESSARY Pump top may be rotate...

Page 6: ...OUTLET TUBE CONNECTION Attach plastic tubing to check valve and secure with hose clamp Route tubing up and away from condensate pump avoid compressing or kinking tubing 1 3 8 Clear vinyl plastic tubin...

Page 7: ...rain tubing into one of the four inlet holes making sure tubing is straight If installing to a humidifier a P trap should be used INLET COVERS 5 INSTALL INLET COVERS Insert inlet covers in remaining c...

Page 8: ...that power to appliance and pump is shut off before attempting this step Failure to follow these warnings will void the warranty and could result in a fatal electric shock Com Run RUN Shut Down Circu...

Page 9: ...s pump is supplied with a grounding conductor and grounding type attachment plug To reduce the risk of electric shock be certain that it is connected only to a properly grounded grounding type recepta...

Page 10: ...e tank with water An amber LED will indicate pump is operating 2 TESTING OVERFLOW SWITCH IF CONNECTED Manually overfill tank with water If overflow safety switch is wired correctly appliance will shut...

Page 11: ...ED INDICATOR STATUS LED STATUS Green LED Indicates pump has power and is ready Amber LED Indicates pump is running and removing condensate from tank Red LED Indicates pump is in alarm mode and that th...

Page 12: ...ank sides away from deck while lifting on pump cover Periodically inspect the condensate pump tank to ensure it is free of accumulated dirt or sludge DO NOT use solvent cleaners Clean tank with soap a...

Page 13: ...et flow Check to ensure that pump safety switch alarm circuit is connected to appliance The safety switch connection will shut off appliance in this condition 3 Check to ensure that pump is level If p...

Page 14: ...t to the point designated in the Company s return authorization This warranty is a limited warranty and shall be in lieu of any other warranties expressed or implied including but not limited to any i...

Page 15: ...s despu s de manipular este producto PRECAUCI N RIESGO DE INUNDACI N Una bomba que no funcione puede producir lesiones personales o da os a la propiedad Si se produce una inundaci n NO camine en el re...

Page 16: ...ba se apaga autom ticamente La bomba tiene capacidad para elevar el agua hasta 6 10 m y est equipada con una v lvula de control que evita que el agua se devuelva al tanque cuando la bomba se apaga La...

Page 17: ...ierta 3 A ULTRACP 22 ULTRACP 22 230 Voltaje calificado 120 voltios 60 Hz 230 voltios 60 Hz Consumo calificado de corriente 1 9 amperios 1 0 amperios Alto de cabezales M ximo de 6 71 m M ximo de 6 71 m...

Page 18: ...la bomba de condensaci n 1B FIJE A LA PARED Fije la bomba de condensaci n con los tornillos 20 32 cm entre las leng etas de montaje OPCI N 2 INVIERTA LA PARTE SUPERIOR SI FUERA NECESARIO La parte sup...

Page 19: ...SALIDA Fije el tubo de pl stico para verificar la v lvula y asegurarlo con la abrazadera para manguera Gu e la tuber a hacia arriba y lejos de la bomba de condensaci n Evite comprimir o retorcer la t...

Page 20: ...os de entrada asegur ndose de que la tuber a est recta Si instala la bomba a un humidificador de condensaci n deber usar una trampa pl stica CUBIERTA 5 INSTALE LAS CUBIERTAS DE ENTRADA Coloque las cub...

Page 21: ...cte un interruptor de seguridad para desbordes como se muestra en el diagrama de cableado ADVERTENCIA Riesgo de descarga el ctrica Aseg rese de que la bomba y el sistema est n apagados antes de intent...

Page 22: ...proporciona con un conector a tierra y un enchufe adicional de tipo polo a tierra Para reducir los riesgos de descarga el ctrica es necesario asegurarse que la conexi n se realiza a un recept culo de...

Page 23: ...Una luz LED mbar indica el funcionamiento correcto del flotante 2 INTERRUPTOR DE REBOSE DE PRUEBA SI EST CONECTADO Sobrellene manualmente el tanque con agua Si el interruptor de seguridad para desbord...

Page 24: ...e Indica que el circuito del sistema CA est funcionando y la bomba est lista Luz LED mbar Indica que la bomba est funcionando y est eliminando la condensaci n del tanque Luz LED roja Indica que la bom...

Page 25: ...mba Inspeccione peri dicamente el tanque de la bomba de condensaci n para asegurarse de que est libre de suciedad o lodo acumulados NO use limpiadores a base de solventes Se debe limpiar el tanque sol...

Page 26: ...que el interruptor de seguridad de la bomba circuito de alarma est conectado al sistema La conexi n del interruptor de seguridad apagar el sistema en esta condici n 3 Aseg rese de que la bomba est niv...

Page 27: ...v o al punto designado en la autorizaci n de devoluci n de la Compa a Esta garant a es limitada y reemplazar cualquier otra garant a expresa o impl cita e incluye pero no se limita a cualquier otra ga...

Page 28: ...Diversitech Corporation Duluth GA 30097 800 995 2222 DOC172637 AsurityTM is a registered trademark of DiversiTech Corporation 2021 DiversiTech Corporation...