Operating instructions
64420 A 98/16
page 16 - 17
-
Remove foreign bodies. Check grinding
discs, rotating and stationary disc flange,
etc. for damage.
All supporting surfaces of stationary disc flange, rotating disc flange, grinding
discs and grinding case must be absolutely clean before assembly.
Only in this way can perfect grinding be guaranteed.
-
Then re-assemble parts in reverse
sequence.
-
Plug in power cable, switch on coffee
grinder briefly.
If the coffee grinder should block or there is a sound of metal parts rubbing
together, the scale setting must be adjusted
according to 3.3.2.
-
Retighten screws (6) of the stationary disc
flange. For this purpose the hopper (4)
must be removed again and then re-fitted
(see illustration page 13).
Retighten hopper lock (3) after reassembly (see illustration page 13).
-
Perform
basic
setting
(calibration)
according to 3.3.1.
4.2.3
Replacing the rubber bolt (KF only)
-
Pull bag holding lever (1).
-
Remove sleeve screw (2) with adequate
wrench (no. 17).
-
Replace old rubber tube (3) with new one.
-
Re-tighten sleeve screw (2) with adequate
wrench and release bag holding lever.
4.2.4
Circuit breaker
-
Set ON/OFF switch to position 0.
-
Close overcurrent release by pressing red
button underneath bottom plate.
-
The coffee grinder is again ready for
operation.
1
2
3