2.4 

Recharging the Battery using DL-5A/5W 

 

(1)

(3) 

(2) 

 

The drop-in charger 

DL-5A/5W

 is designed for connecting 

to 115 VAC or 230 VAC, 50 to 60 Hz mains. 

First of all

check that the unit's operating voltage is identical with your 
local mains supply. If required, set the voltage selector 
switch 

(3)

 by means of a suitable tool to the respective 

voltage, changing of fuses is not required. 

DL-5A/5W 

is 

factory set to 230 VAC! 
Plug the mains cable into a suitable wall outlet. The red 
pilot lamp (

1)

 lights up. 

For charging, insert the complete hand-held transceiver 

FSG 5W

 or just the removed Ni-MH battery pack upright 

into the charging chamber. A certain position of the battery 
pack is not required. 
If the battery is discharged, the charger switches 
immediately to rapid charge (yellow lamp (

2)

 lights up). 

Rapid charge - yellow pilot lamp (2) lights 

The duration of charge depends on the state of the battery and is approx. 10 hours 
at 250 mA (for a 1.5 Ah battery).When the switch-off voltage is reached the charger 
switches automatically to trickle charge. The capacity at the end of rapid charging is 
about 90% of the full rated capacity. 

Trickle charge - yellow pilot lamp (2) goes off 

The Ni-MH battery pack is now continuously charged on low current. The full 
capacity of the battery is thus guaranteed. Overcharging the battery is not possible 
due to automatic and temperature controlled charging function, even if the trickle 
charge is maintained over a long period. 
Batteries in chargers operating on trickle charge are fully charged. 

 

IMPORTANT! 

  To prevent fire or shock hazard, do not expose the unit to rain or 

moisture. 

  To avoid electrical shock, do not open the cabinet. Refer repairing to 

qualified personnel only. 

  The chargers must not be operated on or near heaters or in direct 

sunlight. 

  Charging should be done within the ambient temperature range of 

10°C to +40°C, otherwise the battery may not be fully charged. 

  The VHF Transceiver 

FSG 5W

 with attached battery pack may be 

operated while being inserted into the drop-in charger, e.g. for 
temporary fixed base use. 

  If a fully charged battery is removed briefly from the charger and then 

reinserted the charging cycle starts again from the beginning: brief 
rapid charging (yellow LED lights) followed by trickle charge. The Ni-
MH battery incurs no damage. 

  If the battery is flat it is first recharged on trickle charge until its terminal 

voltage reaches a certain limit where rapid charging switches on 
automatically.

 

Summary of Contents for FSG 5W

Page 1: ...er 2009 Dittel Messtechnik GmbH Avionics Division Erpftinger Stra e 36 86899 Landsberg Germany Telephone 49 0 8191 3351 0 Fax 49 0 8191 3351 49 E Mail info dittel com Internet www dittel com Dittel Me...

Page 2: ...ith electrically conductive material including lead wires Do not transport or store Ni MH batteries with their uncovered terminals Do not strike or drop Ni MH batteries Sharp impacts or concussion to...

Page 3: ...FSG 5W OPERATION MANUAL November 2009 D10177 3 FSG 5W DIMENSIONS...

Page 4: ...rmation 9 2 2 Battery Replacement 9 2 3 Battery Test 9 2 4 Recharging the Battery using DL 5A 5W 11 Section 3 Operating Instructions 13 3 1 Introduction 13 3 2 Preparation for Use 13 3 3 Operation in...

Page 5: ...rain in standby makes 15 to 24 hrs of operation with 10 to 5 in transmit mode from one standard battery charge a reality The solid aluminum case is dust and waterproof enabling the transceiver of bein...

Page 6: ...e Mode When the PTT switch on the radio is released the transceiver will operate in the receive mode Reception on one of the channel frequencies as se lected by the frequency switches will occur The s...

Page 7: ...fire fight ing Naval air and or Army air mission use consisting of 10 pole connector to connect customer s accessories to FSG 5W twist lock sealed F10172 Spare portable helical antenna 118 144 MHz TNC...

Page 8: ...FSG 5W OPERATION MANUAL 8 D10177 November 2009 THIS PAGE INTENTIONALLY LEFT BLANK...

Page 9: ...ect Use only DITTEL Ni MH battery chargers otherwise you risk to lose the 24 months warranty as well as battery performance reliability 2 2 Battery Replacement IMPORTANT When removing or replacing the...

Page 10: ...uentially 5 LEDs ON Battery fully charged 3 to 4 LEDs ON Battery partially discharged reduced operating time 2 or less LEDs ON Battery discharged 11 VDC or less STOP using the radio Charge the battery...

Page 11: ...ull rated capacity Trickle charge yellow pilot lamp 2 goes off The Ni MH battery pack is now continuously charged on low current The full capacity of the battery is thus guaranteed Overcharging the ba...

Page 12: ...FSG 5W OPERATION MANUAL 12 D10177 November 2009...

Page 13: ...ontrol 3 clockwise to turn the radio ON With the MHz 7 and kHz switches 8 set the desired operating frequency on the frequency display 6 Depress the LAMP BATT TEST button 4 and check the battery statu...

Page 14: ...icrophone area 10 as close as possible to the upper lip This technique is necessary because the noise cancelling feature of the micro phone favors sound close to the microphone and discriminates again...

Page 15: ...ircraft supply negative ground or a battery charger may also connected via socket 1 Even the 12 VDC supply of external accessories like our VOX 90 is possible then the FSG 5W must be switched ON In no...

Page 16: ...hen using the transceiver in buildings vehicles or aircraft the radio should always be operated on a suitable external antenna CAUTION During Transmit mode keep antenna radiator tip at least 10 cm awa...

Page 17: ...chable Battery operating time 9 hours to 45 hours depends on operating mode Current consumption Transmit 550 mA or less Receive 150 mA 20 mA at 0 5 W AF power Standby 17 mA 3 mA Antenna impedance 50 O...

Page 18: ...VBatt Headphone output 2 VRMS or more into at least 30 Ohms 4 3 Transmitter Power output 12 VBatt 1 Watt 0 2 W 0 3 W carrier into 50 Ohms ca 3 6 W PEP Frequency Stability 10 ppm 1 5 kHz or better at...

Page 19: ...FSG 5W OPERATION MANUAL November 2009 D10177 19 Appendix A Certificate...

Page 20: ...FSG 5W OPERATION MANUAL 20 D10177 November 2009 THIS PAGE INTENTIONALLY LEFT BLANK...

Page 21: ...FSG 5W OPERATION MANUAL November 2009 D10177 21 FSG 5W Operator s switches controls and indicators...

Reviews: