MOUNTING THE PROFILE

POSITIONING THE MODULES

WIRING

GREEN

BROWN

YELLOW

WHITE

BLACK

PINK

GREY

VIOLET

RED**

BLUE**

POWER SUPPLY

STOP IMPULSE
OPENING SIDE

REVERSE IMPULSE
CLOSING SIDE

TEST OUPTUT***

The transmitter (TX) should be placed next to 

the door edges that need to be protected.

The angle adjustment clip should be next to 

the transmitter.

Turn the module if necessary.

When a module needs to be turned:

1. detach the clips

2. turn them by 180°

3. reattach

NO POWER

NO DETECTION

DETECTION

The module connected to the door controller 

becomes the 

MASTER

.

Plug the SLAVE 

CABLE between 

the modules in 

one of the two 

placements. 

Mount the profiles as close as possible to the closing edge. Leave 2 cm 

for the black end caps. Take the position of the white clips into account 

before drilling and fastening the screws.

*  Output status when sensor is operational 

**   For compliance with EN 16005 and DIN 18650, connection to door controller test output is required.

*** If door controller is not tested: conncect BLUE to 0 V and RED to +12 V - 30 V DC.

To loosen the modules, please use 

a screwdriver.

1

 Please refer to specific operator manual