14
IP2352EN
EN
6.8 Electrical connections
To connect the automation to the control panel, proceed as follows:
• Remove the rear cover [7] as explained in paragraph 6.4.
• Fit the cable gland on the automation, inserting it in the relative threaded hole in the metal
fusion (Fig. 6.2 and 6.3).
• Connect the various wires as shown in the electrical diagram in Fig. 6.4.
• Fasten the rear cover [7] to the gearmotor.
The electrical connections and start-up of the PWR50AC gearmotors are explained in the instal-
lation manuals of the LOGICM / LCA80 control panels.
To increase the protection of the motor cable, a corrugated flexible tube can be used.
M
M
6.7 Reversible and irreversible piston
To make the piston reversible, insert pin [M].
NOTE
: the operation must be carried out with the piston moving.
Removing the pin [M], the piston becomes irreversible, and the release can only be made with the
key (see USER MANUAL).
Fig. 6.2
Fig. 6.3