Ditec Entrematic CS12E User & Installation Manual Download Page 20

20

IP2162EN

EN

•   using keys ↑ and ↓ select the desired function

    

    

•   press the ENTER key to confirm

7.7  Second level menu - RO (Radio Operations)

Display

Description

SR - Remote control storage.

You can directly access the Remote control storage menu even with the dis-
play turned off, but only with the Display visualisation mode option set to 00 
or 03: 
-  for transmitting a remote control not present in the memory;
-  for transmitting an unstored channel of a remote control already present in 
the memory.

...x2, x3...

TX - Visualisation of counter showing remote controls stored 

 16 radiocomandi [esempio]

MU - Indication of maximum number of remote con-
trols that can be stored in the integrated memory.

You can store a maximum of 100 or 200 remote control 
codes.

2”

2”

oppure

20 - 200 storable remote controls
10 - 100 storable remote controls

16 remote controls (example)

RO - Rad

io oper

at

io

ns

or

Summary of Contents for CS12E

Page 1: ...018 09 06 COM Power supply Release microswitch Selection of automation type FACTORY SET blue black grey Closing safety device Step by step Flashing light Antenna Safety stop MOTOR 24V Output 24 V max...

Page 2: ...BA Basic Adjustment 16 7 7 Second level menu RO Radio Operations 20 7 8 Second level menu SF Special Functions 23 7 9 Second level menu CC Cycles Counter 25 7 10 Second level menu AP Advanced Paramet...

Page 3: ...s and directives Good Working Methods instal lation premises system operating logic and the forces developed by the automation Before connecting the power supply make sure the plate data correspond to...

Page 4: ...n of Conformity 3 Technical speci cations i N B The given operating and performance features can only be guaranteed with the use of DITEC Entrematic accessories and safety devices Matteo Fin n n n n n...

Page 5: ...contact activates an opening operation N B Once the automation stops command 1 5 per forms the opposite operation to the one performed before the stop 1 6 NC CLOSING SAFETY DEVICE When selecting openi...

Page 6: ...PAVRS device into the special housing for AUX plug in cards If the test fails an alarm message appears on the display 1 6 NC SAFETY STOP When selecting connect the output contact of the safety device...

Page 7: ...1 IN2 BC GOPAVT OPENING JR3 AUX 5 1 LP 0 1 6 8 8K2 8K2 IN1 1 IN2 41 OUT1 OUT2 GOPAVRS CS12E Examples of installation of self controlled safety edge SOFA15 SOFA20 SOFA25 OPENING JR3 AUX 5 1 LP 0 1 6 8...

Page 8: ...g the function The saved con gurations can be recalled using the function The storage module allows the remote controls to be stored If the control panel is replaced the storage module being used can...

Page 9: ...play on and off i N B pressure on the keys can be quick less than 2 s or prolonged longer than 2 s Unless speci ed otherwise quick pressure is intended 6 Selections Jumper Description OFF ON JR1 Displ...

Page 10: ...pressing of the keys and performs a POWER RESET com mand interruption of the power supply and restart of the automation Keeping press the UP or DOWN key fast menu scrolling begin To stop menu scrolli...

Page 11: ...require at least three operations before they are set correctly RO Radio Operations The menu allows you to manage the radio operations of the control panel SF Special Functions The menu allows you to...

Page 12: ...ion loads prede ned values for certain standard parameters AC enabling of automatic closing enabled TC setting of automatic closing time 1 minute C5 step by step opening command operation step by step...

Page 13: ...advanced parameters menu 2 After activation you can scroll through the third level menus The third level menus are activated for 30 min Depending on the type of automation and control panel some menus...

Page 14: ...ed ON with the automation idle if the contact 1 8 is open all operations are prevented When disabled OF with the automation idle if the contact 1 8 is open opening operations are permitted NI Enabling...

Page 15: ...operation 1 5 Step by step 1 3 Opening AM AUX plug in card operation 1 5 Step by step 1 3 Opening PP Setting step by step sequence from command 1 5 ON Opening Stop Closing Stop Opening OF Opening Sto...

Page 16: ...ifferent intervals of sensitivity from 0 to 59 with intervals of 1 second from 1 to 2 with intervals of 10 seconds 1 00 RP Adjustment of partial opening measurement Adjusts the percentage of operation...

Page 17: ...imum thrust 99 Maximum thrust 50 R1 Adjustment of thrust on obstacles and current during closing The control panel is tted with a safety device which stops or reverses movement when an obstacle is de...

Page 18: ...ime s 0 5 Minimum 3 0 Maximum Neos Super fast 1 0 Minimum 4 0 Maximum 2 0 Neos Super Fast 3 0 TA Adjustment of acceleration time s start speed is 75 of 0 5 Minimum 2 0 Maximum Neos Super fast 1 0 Mini...

Page 19: ...f approach speed during closing cm s Indicates the speed from the end of the deceleration ramp to the end of the stroke 02 Minimum 10 Maximum N B gradually increase the approach speed if there is a se...

Page 20: ...00 or 03 for transmitting a remote control not present in the memory for transmitting an unstored channel of a remote control already present in the memory x2 x3 TX Visualisation of counter showing re...

Page 21: ...sier avoiding the need to continuously press the remote control press the UP or DOWN key once to begin slowly scrolling through the parameters This scrolling movement is faster if the UP or DOWN key i...

Page 22: ...RNING options 1 3 opening and 1 5 step by step are available as an alternative and depend on the selection ER Cancelling a single remote control 2 EA Cancelling an entire memory 2 2 EC Cancelling a si...

Page 23: ...the user con gurations previously saved and on the control panel storage module or upload the prede ned settings available in memory positions and 01 parameter setting for passive edge on closure edge...

Page 24: ...lections and adjustments You can delete the set password by selecting the sequence JR1 ON JR1 OFF JR1 ON IP Inserting the password esempio 2 N B this can only be selected when the password is set Whe...

Page 25: ...y of total operations counter 182 manovre esempio CP Display of partial operations counter 716 manovre esempio CH Display of power supply hour counter 256 ore di alimentazione esempio WARNING dependin...

Page 26: ...ting maintenance alarm display mode 00 Display displays the alarm message 01 Flashing light with the automation closed it ashes 4 times repeating this action every 60 min utes and display it displays...

Page 27: ...limit switch after activation the door wing stops its movement PX Proximity limit switch after activation the door wing continues as far as the end stop and any obstacle is considered a stop with sta...

Page 28: ...sing 02 Automation status see paragraph 8 1 03 Commands and safety devices see paragraph 8 2 WARNING depending on the type of automation and control panel some menus may not be available i N B make ad...

Page 29: ...the opening of the safety contact stops movement with disengage ment if When the contact clos es again the interrupted operation continues 02 During the operation the opening of the safety contact sto...

Page 30: ...ning op eration from a voluntary command 00 Minimum 05 Maximum 00 WC Setting of pre ashing time on closing s Adjustment of the lead time for the switch on of the ashing light in relation to the start...

Page 31: ...s only visible with Display visualisation mode set to 02 Display Description Automation closed Automation closed Release door open Automation open Automation open Release door open Automation stopped...

Page 32: ...open Automation open Automation open Release door open Automation stopped in intermediate position Automation stopped in intermediate position Release door open Automation closing Automation that slo...

Page 33: ...step command 1 6 Safety device with opening and closing stop 1 8 Safety with closing reversal P3 Partial opening command 3P Opening command with operator present 4P Closing command with operator prese...

Page 34: ...obstacle detection limit during closing S1 Detection of stop during closing S2 Detection of stop during opening SW Release door open When the release door is closed the control panel performs a RESET...

Page 35: ...ng an op eration Check connection of motor Check motor brush contacts If the problem persists contact Tech nical Support MD Irregular functioning of motor opening limit switch Check connection of the...

Page 36: ...ht output short circuit alarm Check that the ashing light is working properly Power supply alarm P1 Microswitch voltage too low Check the control panel is powered correctly Control panel internal alar...

Page 37: ...sts contact Tech nical Support IO Interrupted power circuit motor MOSFET open Reset If the problem persists contact Tech nical Support IR Motor relay malfunctioning Reset If the problem persists conta...

Page 38: ...ly move the sliding gate and make sure the entire stroke slides evenly and without friction 5 Switch on and check the automation is operating correctly with the subsequent opening and closing commands...

Page 39: ...f controlled safety edge SAFETY SWITCH release mi croswitch open Check that the hatch is closed correctly and the microswitch makes contact Photocells activated Check that the photocells are clean and...

Page 40: ...l the antenna outside Replace the transmitter bat teries The remote control does not work No storage module or incor rect storage module Switch the automation off and plug in the correct storage modul...

Page 41: ...stacle detection before the activation of the proximity limit switch while opening the door wing stops performing a disengagement operation after the proximity limit switch is activated the door wing...

Page 42: ...lthough the contents of this publication have been drawn up with the greatest care Entrematic Group AB cannot be held responsible in any way for any damage caused by mistakes or omissions in this publ...