SK752 Operator’s Manual
Service - 73
900 Hour
Change Hydraulic Fluid and Filter
Change hydraulic fluid and filter every 600 hours.
Change every 250 hours if jobsite temperature
exceeds 100°F (38°C) more than 50% of the time.
1.
Remove drain plug (3).
2.
Drain fluid and replace plug.
3.
Change filter. See page 70.
4.
Add THF at fill (1) until fluid level is at halfway
point on sight glass (2). Capacity is 9.2 gal
(35 L).
Change Fan Belt
Change fan belt every 600 hours. Belt is properly
tensioned when it moves about 1/4-3/8” (7-9 mm)
when pushed at the long span (shown).
To change:
1.
Loosen alternator bolt (1).
2.
Replace fan belt (2). Adjust position as
needed.
3.
Tighten bolt.
4.
Check tension.
900 Hour
Adjust Valve Clearance
Adjust valve clearance every 900 hours.
To adjust, see a certified Kubota engine technician.
NOTICE:
If valve clearance is adjusted by anyone other than a certified Kubota engine technician,
engine warranties could be voided. Please see engine manual for more information.
t35om029w.eps
1
3
2
1
2
t46om018w.eps
Summary of Contents for SK752
Page 1: ...SK752 Operator s Manual 053 2859 Issue 2 0 Original Instruction...
Page 11: ...Contents 10 SK752 Operator s Manual...
Page 21: ...Safety 20 SK752 Operator s Manual Machine Safety Alerts...
Page 31: ...Controls 30 SK752 Operator s Manual Attachment Plate...
Page 41: ...Prepare 40 SK752 Operator s Manual Connect Attachment...
Page 47: ...Drive 46 SK752 Operator s Manual Shut Down...
Page 55: ...Transport 54 SK752 Operator s Manual Retrieve...
Page 86: ......
Page 87: ......
Page 88: ...SK752 Operator s Manual Service Record 87 Service Record Service Performed Date Hours...
Page 89: ...Service Record 88 SK752 Operator s Manual Service Performed Date Hours...