SK600 Operator’s Manual
Service - 67
Procedures
Belt, Fan
Check every 100 hours. Change every 600 hours.
Check
Check for excessive slack, damage or wear. Belt is
properly tensioned when it moves about 1/4-3/8”
(7-9mm) when pushed at the long span (shown).
Change
1. Loosen two alternator bolts (1,2).
2. Replace belt.
3. Adjust position as needed.
4. Tighten bolts.
5. Check tension.
Brake
Check at startup and every 10 hours.
1. Ensure parking brake pin (shown) moves
freely allowing brake to be set and released.
2. Clean mud and debris from area around pin.
t51om033w.eps
t51om023w.eps