Page 2: ...ed 15 Shock sensor Motion alarm default disabled 15 Announcement tone off ring tone default disabled 16 Performance characteristics Hospital default disabled 17 Call setup ASCOM only with OAPT interface 18 Setting through DTMF 18 Configuration via microphone 19 Special location request default disabled 19 Battery warning as SMS ASCOM only default disabled 19 Personal Alarm default disabled 19 Spec...

Page 3: ...stations whose signals are most strongly received and if necessary additional information through Beacon service ASCOM 9LD Locator The server calculates the position using such transmitted information and shows it in a layout plan at the control center This Operating Manual is meant for the administrator of the facility who is well informed about the DECT technology and has the duty of setting and...

Page 4: ...disty guard operating instructions Application In built RFID Tag as identification for passing through restricted areas or for other authorization purposes Page 4 of 25 Components of an ASCOM system ...

Page 5: ...disty guard operating instructions ASCOM Protocol DECT location service per SMS Page 5 of 25 ASCOM Beacon service ...

Page 6: ...ess a small stick like a paper clip into the outside of the hole from the tag so that the spring bar can be removed Possibility 2 Fastening with the Clip As a prerequisite place the two spring bars as illustrated above Put one side of the belt clip over one spring bar and than over the other Please note that the hole of the clip is placed at the side of the microphone of the distyloactor tag Possi...

Page 7: ...ns to flash This indicates that the disty guard is searching for the base station that is ready for subscription The DECT base station is activated for the subscription process Ensure that no other base station DECT system has activated subscription readiness You will hear a Beep after successful subscription and the device will restart to accept the data The subscription process is thus completed...

Page 8: ...tered in the device through the programming station PS see chapter on Requesting Setting parameters and functions Function 14 Subscription is now performed as described above Configuration Some settings were made in the device during production which shall be adapted to the respective purpose of application For this purpose see the section on Requesting Setting parameters as well as Configuration ...

Page 9: ... up DECT activity is halted Factory setting The following operating procedure is performed to reset to delivery status factory setting default which will work only when the device is subscribed Set disty guard to CS Red LED illuminates as confirmation and acoustic beep signal is heard Press the alarm key latest after 5 seconds and hold for 10 seconds Green LED illuminates Let go of alarm key befor...

Page 10: ... up to eight digits 0000 PIN 0000 Special location request PC number Not active Beacon service ASCOM location device 9dLD Not active Special location alarm Beacon service Not active SMS on low battery Not active Ring tone Active Personal alarm Alarm button acts as on a ASCOM Handset and sends a SMS Not active Note Alternatively default status can be established through the programming station see ...

Page 11: ...to the station without entering a command A PC with USB connection is required to use the PS for the setting of parameters The PS will now be connected to the PC through a USB cable Note If applicable the installation of a driver Virtual Com Port may be required CDC driver USBLadestation inf The disty guard is not plugged during installation The programming tool disty Programmer App can be downloa...

Page 12: ...s recognized the disty guard the communication begins the LEDs of the tag will blink The status line will light up in green color The tool is ready for use Now you can choose the function or value you want to change As an Example alarm number go to sheet Configuration 1 write the appropriate number which shall be dialed by pressing the alarm button into the field Alarm number initiate the transmis...

Page 13: ...ay several parameters can be set to your needs In the end you stop the mode by pressing the upper left button The PS can be used as charging station Therefore no PC connection is needed The disty guard is plugged in and out as usual Page 13 of 25 ...

Page 14: ...ASCOM facilities Emergency call default disabled If the button is pressed for longer than 3 seconds in a normal state a link will be established with a programmed number the red LED flashes That is a speech connection This can be terminated only by pressing the button again The emergency call is set through Function 10 If a disty guard is called which has no emergency number set then it stores the...

Page 15: ...ult disabled Performance characteristics serve the purpose of recognizing an accident on the part of the bearer e g fainting non usage of the device or touching of a secured object If the acceleration values of the sensor fall short of a specific value threshold for a specific amount of time time out alarm will be triggered Mode Quiescence man down alarm Alarm is reported in the mode active moved ...

Page 16: ...t 240 seconds Alarm time of 4 minutes must be set through configuration Programming station PS Function 21 If the device is not moved for a minimum of 4 minutes the respective SMS will be displayed at the OAPT interface The precise format is listed further behind MD Alternatively a call is put through to the preset number b Function Motion Detection Timeout 180 seconds The function as well as the ...

Page 17: ...least 10 minutes and dispatches a SMS message Alarm Coordinates depending on configuration Patient receives visual and acoustic feedback Nurse is informed through her handset and can gets back to patient After 10 minutes the device switches off again and is ready for new alarm The following parameters are used as setting Emergency number Function 10 Locator options Function 24 3 Page 17 of 25 ...

Page 18: ...rd for this purpose and the remote subscriber sends the respective sign After recognizing the desired setting in this case the introductory sign 9 a one minute countdown begins for the modification of the desired parameter Following successful programming a positive acknowledgment tone will sound and the connection will be terminated Only one parameter can be modified Authentication Code AC 9 pin ...

Page 19: ...guard and now select the above described combinations of numbers on the push button at the telephone The successful programming is indicated by a positive acknowledgment tone If you want to change other parameters this procedure must be repeated accordingly Special location request default disabled For certain pabx the current location of the user terminal is determined by a short call This proces...

Page 20: ...3 man down at the beginning of a call if the shocksensor is enabled and the situation of man down was raised SMS messages OAPT 2011 12 05 For an complete overview of the implemented protocol please refer to the documents SSD Ascom IP DECT concept B pdf SSG Bedienungsanleitung pdf Product approval CE mark Disty communications GmbH hereby declares that the disty guard conforms to the fundamental req...

Page 21: ...evice CS designed for this purpose Charging takes approximately 12 hours for a complete charging cycle Power supply plug 12 VDC 150 mA Single 1500 mA Multiple station Plug 5 5 2 1 mm interior exterior Operating temperature 0 C to 40 C Storage temperature 20 C to 60 C Page 21 of 25 Multiple CS disty guard charger 10 Wall mounting Charging station disty guard charger 1 Table device ...

Page 22: ... out of range searching for base station Red LED flashes every second 8 DECT connection Green LED is switched on 9 Alarm Red LED flashes once in every 0 5 seconds 10 Range Limit Red LED flashes fast Warning tone 11 Status on delivery Default Press of button Red and green LED on 12 Programming through DTMF Green LED flashes It is fixed in factory settings that DECT activity turns off when the disty...

Page 23: ...d LED illuminates green LED flashes Transmitting data5 Charging voltage too low PS is in data transfer mode Green and red LED flash together for 3 seconds Package list The following items will be found together with the disty guard in the box disty guard two spring bars Strap for the upper arm with Velcro Belt clip Lanyard Wristband Operating manual Carton Charging Programming station incl Power s...

Page 24: ...con Service Talk time up to six hours Charging Programming method inductive information transmission through SMS7 Motion sensor Loudspeaker for acoustic signaling or speech output Button for emergency call and operation LEDs for operative display 2 colors Sealing Abutting edge Button material in soft plastic Microphone Lithium ion battery Capacity 450 mAh 3 7 V Charging time about 12 hrs for a com...

Page 25: ... SARI c 128 14 set SARI c 127 0 ffff ffff 15 read PLI LAL ZAP c 36 16 read PARK c 32 17 read IPEI c 34 18 read volume c 67 33 19 set volume 4 2 c 66 33 3 1 20 read shocksensor c 67 27 21 set shocksensor 120 s c 66 27 1 78 22 read range alarm c 67 2b 23 read locator options c 67 3a 24 1 set locator option c 66 3a 1 0 24 2 set locator option c 66 3a 2 0 24 3 set locator option c 66 3a 4 0 24 4 set l...