ELECTRICAL ADJUSTMENTS
D-2
2-6: SUB TINT/SUB COLOR
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
Receive the color bar pattern. (RF Input)
Connect the oscilloscope to pin 6 of CP601.
Activate the adjustment mode display of Fig. 1-1 and
press the channel button (22) on the remote control to
select "TINT".
Press the VOL. UP/DOWN button on the remote control
until the section "A" becomes as straight line.
(Refer to Fig. 2-1)
Connect the oscilloscope to pin 7 of CP601.
Activate the adjustment mode display of Fig. 1-1 and
press the channel button (19) on the remote control to
select "COL.CENT".
Adjust the VOLTS RANGE VARIABLE knob of the
oscilloscope until the range between white 100% and
0% is set to 4 scales
Press the VOL. UP/DOWN button on the remote control
until the red color level is adjusted to 100%
±
10% of the
white level. (Refer to Fig. 2-2)
Receive the color bar pattern. (Audio Video Input)
Connect the oscilloscope to pin 6 of CP601.
Activate the adjustment mode display of Fig. 1-1 and
press the channel button (22) on the remote control to
select "TINT".
Press the VOL. UP/DOWN button on the remote control
until the section "A" becomes as straight line.
(Refer to Fig. 2-3)
Connect the oscilloscope to pin 7 of CP601.
Activate the adjustment mode display of Fig. 1-1 and
press the channel button (19) on the remote control to
select "COL.CENT".
Adjust the VOLTS RANGE VARIABLE knob of the
oscilloscope until the range between white 100% and
0% is set to 4 scales
Press the VOL. UP/DOWN button on the remote control
until the red color level is adjusted to 100%
±
10% of the
white level. (Refer to Fig. 2-4)
Fig. 2-1
White 100%
Red 100%
Fig. 2-2
"A"
Fig. 2-3
White 100%
Red 100%
Fig. 2-4
"A"
2-7: HORIZONTAL PHASE
1.
2.
3.
4.
Receive the monoscope pattern.
Using the adjustment control, set the brightness and
contrast to normal position.
Activate the adjustment mode display of Fig. 1-1 and
press the channel button (05) on the remote control to
select "H.PHAS".
Press the VOL. UP/DOWN button on the remote
control until the SHIFT quantity of the OVER SCAN
on right and left becomes minimum.
2-8: VERTICAL SHIFT
1.
2.
3.
Receive the monoscope pattern.
Activate the adjustment mode display of Fig. 1-1
and press the channel button (07) on the remote
control to select "V.SFT".
Press the VOL. UP/DOWN button on the remote
control until the horizontal line becomes fit to the
notch of the shadow mask.
2-9: VERTICAL SIZE
1.
2.
3.
4.
5.
Receive the monoscope pattern.
Using the adjustment control, set the brightness and
contrast to normal position.
Activate the adjustment mode display of Fig. 1-1 and
press the channel button (06) on the remote control to
select "V.SIZE".
Press the VOL. UP/DOWN button on the remote control
until the SHIFT quantity of the OVER SCAN on upside
and downside becomes 10
±
2%.
Receive a broadcast and check if the picture is normal.