background image

2. Advanced settings

To adjust the settings press        or

Press        so that the screen is off.

Then press and hold        +        together. The unit enters 
the menu at Status 1: “SEN” and in Function 00 (flashing). 

These are advanced settings and should be adjusted with caution.

To move through menu Items 1-7 press the          button.

See the menu below

2.1 

ENTERING INTO ADVANCED SETTINGS MENU* 

TherMiser TME operation

To prevent tampering and adjustment of the TherMiser unit, unit, press        for 5 
seconds       appears. To unlock, press       for 5 seconds       flashes then disappears.

Manual Override      . Press       or       to override current target temp.        appears 
and      if heat required. Automatically resets to program mode at next time interval.  

MENU NO.

ICON

FUNCTION

OPTIONS

FACTORY SETTING

1

SEN

Controls sensor inputs

00: Built-in temp sensor only

01: External temp sensor only

02: Built in temp and External Skirting Temp Sensor

Note: If no external sensor fitted,“ERR” message 

displays, unit will not function

00

2

OSV

Upper limit of external/ThermaSkirt sensing temp,

5~99°C

42°C

3

DIF

Differential hysteresis between off and on again  

of external temp.

1~9°C

2°C

4

SFH

Room temperature upper limit

5~99°C

35°C

5

SVL

Room temperature lower limit

5~99°C

5°C

6

ADJ

Calibrates tem of unit to the room, compensating  

for external factors.

-5~+5°

0°C

7

FRE

Frost protection

00: Frost protection OFF

01: Frost protection ON. 5°C

00

8

PON

Power on memory

00: Auto memory, no power

01: NO power = no memory

00

9

FAC

Factory reset

Adjust using     until“00”

then press      to restore 

factory settings

00

2.2 

LOCK SCREEN/MENU

 

2.3 

LOCK SCREEN/MENU

 

Visit 

www.discreteheat.com/thermiser

 for more information

All manuals and user guides at all-guides.com

Reviews: