2. Advanced settings
To adjust the settings press or
Press so that the screen is off.
Then press and hold + together. The unit enters
the menu at Status 1: “SEN” and in Function 00 (flashing).
*
These are advanced settings and should be adjusted with caution.
To move through menu Items 1-7 press the button.
See the menu below
2.1
ENTERING INTO ADVANCED SETTINGS MENU*
TherMiser TME operation
To prevent tampering and adjustment of the TherMiser unit, unit, press for 5
seconds appears. To unlock, press for 5 seconds flashes then disappears.
Manual Override . Press or to override current target temp. appears
and if heat required. Automatically resets to program mode at next time interval.
MENU NO.
ICON
FUNCTION
OPTIONS
FACTORY SETTING
1
SEN
Controls sensor inputs
00: Built-in temp sensor only
01: External temp sensor only
02: Built in temp and External Skirting Temp Sensor
Note: If no external sensor fitted,“ERR” message
displays, unit will not function
00
2
OSV
Upper limit of external/ThermaSkirt sensing temp,
5~99°C
42°C
3
DIF
Differential hysteresis between off and on again
of external temp.
1~9°C
2°C
4
SFH
Room temperature upper limit
5~99°C
35°C
5
SVL
Room temperature lower limit
5~99°C
5°C
6
ADJ
Calibrates tem of unit to the room, compensating
for external factors.
-5~+5°
0°C
7
FRE
Frost protection
00: Frost protection OFF
01: Frost protection ON. 5°C
00
8
PON
Power on memory
00: Auto memory, no power
01: NO power = no memory
00
9
FAC
Factory reset
Adjust using until“00”
then press to restore
factory settings
00
2.2