background image

2.2 Wall Mount Overview

Each battery requires a separate bracket. Attach the bracket to the wall before attaching the AES battery to the wall mount.

Each bracket requires a minimum of four 1/4 inch diameter lag bolts or other fasteners. Fasteners must be strong enough to 
support 227 kg (500 lbs).

Mounting Surface

Minimum Required Fastener

Minimum Number of  

Fasteners Per Wall Mount

Wood Studs 16 inch on-center

1/4 inch Diameter x 3 1/2 inch long lag bolt

4

Wood studs not 16 inch on-center  

(3/4 inch min. plywood panel required) 

1/4 inch diameter x 1 inch long wood screw

6

Steel studs at 16 inch on-center (min. 18 gauge)

1/4 inch diameter self-drilling screw

4

 

 

 

NOTE

If the wall does not have 16 inch on-center studs, adequate 

support for the bracket will have to be provided. For example, a 

sheet of plywood can be attached to the wall, and the bracket can 

then be attached to the plywood.

4

discoverbattery.com

18.72in

3.19in

4.25in

4.25in

4.25in

3.19in

3.19in

3.19in

17.18in

12in

16in

1.77in

 17.18

13.20 

 4.25

 4.25

 2.8

 2.8 

2.8

16 

 12 

950-0019 AES Wall Mount 

Bracket for AES 42-48-6650

950-0023 AES Wall Mount 

Bracket for AES 44-48-3000