1. Safety

1.1 Warnings, Cautions and Notes 

 WARNING

Death or Injury 

 CAUTION

Equipment Damage

 

NOTE

Additional Information

1.2 General Warnings

 

WARNING

HAZARD OF ELECTRICAL SHOCK AND FIRE

• 

Connect LYNK to only Safety Extra Low Voltage (SELV) 

circuits and power sources.

• 

All wiring must be completed by qualified personnel to 

ensure compliance with applicable installation codes 

and regulations.

Failure to follow these instructions can result in death or 

serious injury.

 

CAUTION

HAZARD OF EQUIPMENT DAMAGE

• 

Do not install LYNK outdoors.

• 

Do not connect any port of the LYNK to a network 

with power over Ethernet (PoE) or to a public 

telecommunication network. 

• 

Do not run CAT5 cables or other cables connected 

to LYNK through conduit that could be exposed to 

lightning strikes.

Failure to follow these instructions can damage equipment.

 

Summary of Contents for 950-0016-SLRK

Page 1: ...pacity 4 PN 950 0016 SLRK LYNK Edge Card Sol Ark User Manual 4 13511 Crestwood Place Richmond BC V6V 2E9 Canada 1 778 776 3288 info discoverbattery com discoverbattery com 805 0029 REV A 4 Installing...

Page 2: ...ified personnel to ensure compliance with applicable installation codes and regulations Failure to follow these instructions can result in death or serious injury CAUTION HAZARD OF EQUIPMENT DAMAGE Do...

Page 3: ...08 0005 44 24 2800 data sheet Discover Energy 808 0027 44 48 3000 data sheet Discover Energy 805 0015 AES LiFePO4 battery 44 24 2800 42 48 6650 manual Discover Energy 805 0025 AES LiFePO4 battery 44 2...

Page 4: ...communication port 3 2 Minimum Battery Capacity Battery charge and discharge rates are managed automatically by the AES LiFePO4 battery and Sol Ark device Using very large solar arrays with battery ba...

Page 5: ...wrap to color code the cable Terminal surface Lock washer supplied with battery Flat washer supplied with battery Battery cable lug Ensure nothing is between the terminal surface and the battery cabl...

Page 6: ...k Edge Card port and the other end into the Sol Ark inverter CAN port L1 L2 PV1 PV1 PV2 PV2 Load Out AC In Out Gen In 50A 50A 50A PV Input DC Input Batt Disconnect Neutral Ground L1 L2 L1 L2 CAN RS485...

Page 7: ...inverter and navigate to the BATT tab in the Basic Setup Menu and ensure that BMS Lithium Battery is enabled with a check mark and displays 00 00 00 Refer to the most recently published Sol Ark manual...

Reviews: