Impianti aspirapolvere centralizzati
Zentralstaubsauganlagen
Central vacuum systems
Système d’aspiration centralisée
3.1 Positioning the cleaner.
The cleaner is installed in the celler,
garage or in another service room,
where a sufficient ventilation is granted.
Do not install near other warm sources.
It is possible to install the cleaner on the
balcony. In this case it has to be protect-
ed from the weather conditions.
In any case respect the following
mini mal distances.
3.2 Mounting
Before installing the cleaner it is ne-
cessary to fix on the wall the mounting
bar enclosed in the dust container.
Use only the included bar and mount
it properly, just in accordance to the
kind of wall and using the appropriate
tools and steel screws:
Install the cleaner on the wall mount-
ing bar, taking care to the alignment,
the stability and the security.
3.3 Connections
- To the inlet tubing through the self
strengthen rubber hoses enclosed
in the parcel (rubber hoses and
silencer are not included of the
models ZSA 18/1 and ZSA 25/1).
- To the outlet tubing through the
other self strengthen rubber hoses
enclosed in the parcel.
- Low voltage connections: To the
branch low voltage cables connect-
ed with the micro switches or pin
jacks in the inlets. Eventually
through the electric shunt box.
- To the feeding (220-230 Volt)
through the SCHUCO socket:
In order to prevent the limited electro-
shocking danger, these connections
are to be made in security and with
adequate tools.
recomended distances for rooms with heightness up to 240 cm.
ELECTRIC
INLET
220/230 V
ELECTRIC
SHUNT BOX
12 V
OUT
IN
CeNTrAL Distances in cm
VACUUM CLeANer
Mod. 18/1 136 108 129,5 142 164 33 47
Mod. 25/1 165 108 144,5 156 175 33 47
Mod. 25/2/DD 171 108 168 185,5 205 33 47
Mod. 45/2-3/DD 181,5 100 183,5 204,5 225 36,5 50,5
1 2 3 4 5 6 7