  Load And Circuit Breaker: 

The total combined load 

through the outlet on the generator must not exceed the 

rated maximum power (800 watts) of the unit. Always 

reduce the load if the AC circuit breaker turns off. Once the 

load is reduced, press the breaker to reset the generator and 

continue operation.

8.  

Calculating Power Draw:

 Power draw can be calculated by 

multiplying volts and amps. The resulting number is wattage.

Never exceed the rated maximum wattage (800) for the 

generator or outlet. Refer to appliance/tool owner’s manuals 

to determine the wattage of electrical load devices.

Note: Long power cords and extension cords draw additional 

power. Keep cord length at a minimum.

9.  

AC Application: 

Allow the engine to run at no load until 

warm (approx. 3 minutes) after each start-up to allow the 

engine to stabilize.

10.  Plug the power cord of the 120 volt appliance/tool into the 

120 volt AC outlet on the generator (see Figure 3).

Do not allow the generator to completely run out of fuel with 

devices attached. A generator’s output may sharply spike as it 

runs out of fuel, causing damage to attached devices.

11.  When finished using the appliance/tool, unplug its power 

cord from the AC outlet on the generator (see Figure 4).

12.  

Generator Shut Off:

 Remove all electrical load 

devices from the generator. Allow the engine to run for 

approximately 3 minutes with no electrical load.

13.  Turn the generator’s power switch to OFF to stop the 

engine (see Figure 5).

14. Turn the fuel valve to the OFF position.

15.  Allow the generator to completely cool down before 

storing, at least 20 minutes.

16.  For any lengthy time of storage, more than 20 days,  

completely empty the fuel from the generator’s fuel tank 

and engine’s fuel lines. Cover and store in a well ventilated 

area.

!

CAUTION

Disconnect

Powered 

Devices

Before

Startup or

 Shutdown

Shutoff

Under 

Load 

Damages 
Generator

Unit Can Power Any One of the Following Items:

Running

Watts

Start-up

Watts

1/4 HP Air Compressor 

600 

900

1/6 HP Motor 

 

500 

800

3/8” 

Drill 

  400 

600

Mini Refrigerator   

400 

700

Table/Box Fan 

 

200

15 Amp Battery Charger 

380

String Trimmer 

 

350

Hedge Trimmer 

 

500

Radio 

  50

Ten 75W Light Bulbs 

750

101

126

Figure 3

Figure 5

CLOSE

FUEL 

VALVE

POWER

OFF

Figure 4

Summary of Contents for 101172

Page 1: ...WATTS PORTABLE POWER GENERATOR This safety alert symbol identifies important safety messages in this manual Failure to follow this important safety information may result in serious injury or death M...

Page 2: ...1100 W 120th Ave Suite 600 Westminster CO 80234 720 287 5182 For Service or Questions Call 1 877 487 8275 720 287 5182 www dirtyhandtools com Dirty Hand Tools is a brand of...

Page 3: ...mation 4 Unpacking and Setup 7 Filling with Gasoline and Oil 8 Operation Precautions 9 Operation 11 Maintenance 13 Troubleshooting 15 Storage 17 Wiring Diagram 17 Parts List 18 Generator Assembly 19 W...

Page 4: ...you have any questions or concerns about the safe operation of this equipment Intended Use Do Not Use the portable power generator for any purpose other than for which it was designed Any other use i...

Page 5: ...ol drugs or medication Do not allow a person who is tired or otherwise impaired or not completely alert to operate the portable power generator NEVER place fingers hands or body near the generator whe...

Page 6: ...of such parts could create a fire hazard The muffler and engine become very hot with use and can cause a severe burn do not touch Allow the engine to cool before refueling doing maintenance or making...

Page 7: ...ECEPTACLE GROUND TERMINAL on back Unpacking and Setup Your portable power generator is assembled at the factory with the exception of the carrying handle which is packed separately and must be attache...

Page 8: ...x one gallon of 89 octane gasoline with 2 5 fl oz of two stroke engine oil in an approved container Slowly shake the container to thoroughly mix the gasoline 2 cycle oil Do not run the engine with an...

Page 9: ...while the engine is running 6 Do not leave the generator unattended when it is running Turn off the engine before leaving the area 7 Do not operate in explosive atmospheres such as in the presence of...

Page 10: ...connect the appliance and determine whether the problem is the appliance or if the rated load capacity of the generator has been exceeded 3 Make sure that the electrical rating of the tool or applianc...

Page 11: ...Pull the recoil starter with a rapid full arm stroke allowing the starter rope to rewind slowly Repeat as necessary until the engine starts running 6 After the engine warms up and starts running norma...

Page 12: ...es attached A generator s output may sharply spike as it runs out of fuel causing damage to attached devices 11 When finished using the appliance tool unplug its power cord from the AC outlet on the g...

Page 13: ...cedures WARNING Maintenance Before Monthly Every 6 Mo Annually Procedure Each Use 20 Hours 100 Hours 200 Hours Check Engine Gas Oil Mix Level X X X X Check General Equipment Condition X Check Air Clea...

Page 14: ...1 Disconnect spark plug wire from end of plug Clean out debris from around the spark plug 2 Using the spark plug wrench provided remove the spark plug Inspect the spark plug If the electrode is oily...

Page 15: ...g storage Remove spark plug Pour tablespoon of oil into spark plug hole Replace spark plug Crank engine a few times and try to start If the engine still will not start visit our web site at www dirtyh...

Page 16: ...ty capacitor Replace capacitor Engine speed is too fast Adjust engine speed Requires qualified technician Low output voltage under load Open rectifier Test rectifier and replace if required Engine spe...

Page 17: ...e the spark plug wire disconnected Pull recoil starter handle to distribute oil in the cylinder Stop after one or two revolutions when you feel the piston start the compression stroke when you start t...

Page 18: ...l Assy 1 37 Clamp 1 38 Spring Washer 6 7 39 Cross Round Head Bolt M6 x 16 2 40 Flywheel 1 41 Flange Nut M10 x 1 25 1 42 Recoil Starter Assy 1 Part Description Qty 43 Intake Valve Gasket 1 44 Intake Va...

Page 19: ...The parts list and assembly drawing are provided as a reference tool only It is recommended that any repairs or parts replacement be done by a qualified technician User repair and parts replacement m...

Page 20: ...ow for future reference Model No Serial No Date of Purchase Place of Purchase SKU Part No 101172 Description 900W Portable Power Generator Peak Wattage 900 Watts Continuous Wattage 800 Watts Maximum C...

Reviews: