background image

Product Specifications 

 

M1-203D-TR Optical DVI Extension Modules 

 

Compliance 

with 

DVI 

standard: 

Supports 

DVI1.0, 

fully 

implemented  by  fiber-optic  communication  and  DDC2B  by  virtual 
DDC.

 

 

Extension limit: 

2Km (6600feet) for WUXGA (1920x1200) at 60 Hz 

refresh rate.

 

Fiber Type 

Extension Length at WUXGA 

Multi-mode Fiber 

500m 

Single-mode Fiber 

2000m 

 

Graphic  transmission  bandwidth: 

Supports  up  to  WUXGA  at 

60Hz, or 1.65Gbps bandwidth per graphic channel.

 

 

Fiber-optic  connection: 

The  transmitter  and  receiver  modules  of 

M1-203D-TR  have  two  LC  receptacles  so  as  to  be  connected  with 

one  LC  duplex  single  or  multi-mode  fibers,  having  9(8)/125

m  or 

62.5(50)/125

m core.

 

 

DDC connection: 

Virtual DDC by Auto EDID programming.

 

 

Mechanical specifications of transmitter and receiver modules 

 

Dimensions:

 108mm / 25mm / 115mm (W/H/D) 

 

Environmental Specifications 

 

Operating temperature: 0°C to 50°C

 

 

Storage temperature: - 10°C to 85°C

 

 

Humidity: 5% to 85%

 

 

AC/DC Power Adapter 

 

Power Input:

 AC 100-240V, 50/60Hz

 

 

 

Power Output:

 +12 V, 3A SMPS DC-power Adapter 

 

Cord DC Jack: 

Core is 5 V and outer is GND.

 

 
 
1-7 Product Specifications

 

Warranty Information

 

 

1 (One) Year Warranty 

Opticis  warrants this optical DVI  extension module to  be free from defects in 
workmanship  and  materials,  under  normal  use  and  service,  for  a  period  of 
one (1) year from the date of purchase from Opticis or its authorized resellers. 
 
If a product does not work as warranted during the applicable warranty period, 
Opticis  shall,  at  its  option  and  expense,  repair  the  defective  product  or  part, 
deliver to customer an equivalent product or part to replace the defective item, 
or refund to customer the purchase price paid for the defective product.  
 
All products that are replaced will become the property of Opticis.  
 
Replacement products may be new or reconditioned. 
 
Any replaced or repaired product or part has a ninety (90) day warranty or the 
reminder of the initial warranty period, whichever is longer. 
 
Opticis  shall  not  be  responsible  for  any  software,  firmware,  information,  or 
memory  data  of  customer  contained  in,  stored  on,  or  integrated  with  any 
products returned to Opticis for repair under warranty or not. 
 

Warranty Limitation and Exclusion 

Opticis shall have no further obligation under the foregoing limited warranty if 
the  product  has  been  damaged  due  to  abuse,  misuse,  neglect,  accident, 
unusual  physical  or  electrical  stress,  unauthorized  modifications,  tampering, 
alterations,  or  service  other  than  by  Opticis  or  its  authorized  agents,  causes 
other  than  from  ordinary  use  or  failure  to  properly  use  the  product  in  the 
application for which said product is intended. 
 

Dispose of Old Electrical & Electronic Equipment 

(Applicable in the European Union and other European countries with separate systems) 

 

This  symbol  on  the  product  or  on  its  packaging  indicates  that  this 
product  shall  not  be  treated  as  household  waste.  Instead  it  shall  be 
handed  over  to  the  applicable  collection  point  for  the  recycling  of 
electrical  and  electronic  equipment.  By  ensuring  this  product  is 
disposed  of  correctly,  you  will  help  prevent  potential  negative 
consequences  for  the  environment  and  human  health,  which  could 
otherwise be caused by inappropriate waste handling of this product.

 

The  recycling  of  materials  will  help  to  conserve  natural  resources.  For  more  detailed 
information  about  recycling  of  this  product,  please  contact  your  local  city  office,  your 
household waste disposal service or the shop where you purchased the product.

 

 
 
1-8 Warranty Information 

Summary of Contents for M1-203D-TR

Page 1: ...port 1 6 Product Specifications 1 7 Warranty Information 1 8 Regulatory Statements 1 9 Pictorials Figure 1 Schematic Connection Diagram of Optical DVI Audio Extension Modules 1 1 Figure 2 Connection of power adapter to the transmitter 1 3 Figure 3 Connection of power adapter to the receiver 1 3 Figure 4 Connection of optical fibers 1 4 Figure 5 Connection of transmitter to DVI Audio source1 4 Figu...

Page 2: ...before shipment as a default Shipping Group M1 203D TR Optical DVI Extension Module One 1 pair DC power adapter Two 2 units User s Manual Option Product Duplex LC Patch Cord Single or Multi mode fiber Figure 1 Schematic Connection Diagram of Optical DVI Audio Extension Modules 1 1 Welcome Product Description System Requirements for Setup Hardware requirements You have to have a DVI graphic control...

Page 3: ...t Figure 3 Connection of power adapter to the receiver 1 3 Installation Step 5 Connect LC optical fiber between the transmitter and the receiver as shown in figure 4 1 of transmitter should be connected to 1 of receiver and 2 of transmitter should be connected to 2 of receiver by fibers Figure 4 Connection of optical fibers Note Both of single and multi mode fibers are applicable up to 500meters I...

Page 4: ...elf EDID Programming Procedure Troubleshooting The display displays only black screen Ensure that all plugs and jacks used by external power supplies both Opticis and others are firmly connected Ensure the red for Power and green for Optic LED ON Ensure that the DVI ports are firmly plugged in to the PC and display Ensure that the transmitter and receiver modules plugged correctly to the PC and di...

Page 5: ...e paid for the defective product All products that are replaced will become the property of Opticis Replacement products may be new or reconditioned Any replaced or repaired product or part has a ninety 90 day warranty or the reminder of the initial warranty period whichever is longer Opticis shall not be responsible for any software firmware information or memory data of customer contained in sto...

Page 6: ...e Increase the separation between the equipment Connect the equipment into an outlet on a circuit different from that to which the other device s are connected Consult the manufacturer or field service technician for help Type of protection against electric shock Class I equipment Degree of protection against electric shock Not classified no applied parts Classification according to the degree of ...