DirectOut Technologies
®
page 32 of 58
© 2012
DirectOut GmbH
D.O.TEC
®
MA2CHBOX.XT Manual Version 1.2
Chapter 4: Operation
display content
Meaning
A<x> (Menu)
selected audio input for monitoring is
indicated.
Values: AM = Main / A1 = EC 1 / A2 = EC 2
/ AA = AES
AM (Main) refers to the active MADI input
depending on the priority setting. See „P<x>
e<x> (Menu)
selected operating mode is indicated.
Values: E0 = EC mode off / E1 = EC mode on
f<x> (Menu)
selected input scaling factor is indicated.
Values: 1 = 1 FS / 2 = 2 FS / 4 = 4 FS
A 96k Frame signal will override the
setting and force the scaling factor to 2 FS
temporarily
.
The set value is restored once
a 48k Frame signal is detected. Override is
indicated by blinking display of 1 FS or 4 FS.
l<x> (Menu)
level metering during idle mode.
Values: 0 = off / 1 = on
After a short period of time without using the
encoder knob the idle mode is activated.
The display then indicates the input level for the
left and right channel individually. The three
horizontal bars of the segment display mark
the values -30 dBFS, -18 dBFS and -6 dBFS.
The decimal point indicates a signal different
from digital zero.
Press the encoder knob for more than 2 seconds to
enter the
menu
.