page 12 of 16
BREAKOUT Series Hardware Guide - Version 2.0
Chapter 3: Installation
Chapter 3: Installation
Installing the Device
1.
Open the packaging and check that the contents have been delivered
complete and undamaged.
2.
Place the device on a non-slip horizontal surface.
NOTE
Ensure that all concerned devices are switched off before connecting.
3.
Check the patch chords for appropriate pinout and impedance.
Model
Patch chord
BREAKOUT.AN8
BREAKOUT.AN16I
BREAKOUT.AN16O
analog, one to one wired DSUB-25 cable
e.g. DSUB25.AN50 or DSUB25.AN100
- see "Accessories" on page 11
BREAKOUT.AES
BREAKOUT.AESid*
digital*, cross wired DSUB-25 cable
e.g. DSUB25.AES50 or DSUB25.AES100
- see "Accessories" on page 11
* For connecting digital signals the use of cables with 110 Ω impedance is
required.
4.
Connect the DSUB-25 ports using appropriate DSUB-25 cables with AES59
pinout.
For connection with PRODIGY Series or ANDIAMO Series patch chords with
DSUB-25 male to DSUB-25 male connectors are required.