5. PPrrooggrraam

m  tthhee  FFeeaattuurree..  While HOLDING the Valet/Program switch, you can

toggle the feature on and off using the transmitter/receiver. Pressing the lock
button will select the one chirp setting. Pressing the unlock button will select
the two chirp setting. (See 

System Features Menus

section of this guide.) 

NOTE: Some features have more than two settings. Pressing the lock button
selects the one-chirp setting; pressing the unlock button will cycle through all
possible two-chirp settings.

6.  R

Reelleeaassee  tthhee  V

Vaalleett//PPrrooggrraam

m  SSw

wiittcchh..

Once a feature is programmed:

Other features can be programmed within the same menu.

Another menu can be selected.

The learn routine can be exited if programming is complete. 

To access another feature in the same menu:

1. Press and release the Valet/Program switch the number of times necessary to advance from the

feature you just programmed to the next one you want to program. 

2. Then press the Valet/Program switch once more and HOLD it. 

For example, if you just programmed the third feature in the menu and you would like to program
the seventh feature in the menu, you would press and release the Valet/Program switch four times
and then press it once more and HOLD it. The siren would chirp seven times to confirm access to
the seventh feature.

To select another menu:

1. Press and HOLD the Valet/Program switch.
2. After three seconds, the unit will advance to the next menu and the siren will chirp, indicating

which menu has been accessed. 

For instance, if you just programmed some features in Menu #1 (Basic Features) and you wish to
program a feature in Menu #2, you press and HOLD the Valet/Program button. After three
seconds, the siren chirps twice indicating access to Menu #2.

To exit the learn routine do one of the following:

Close the open door. 

Turn the ignition on.

Summary of Contents for Python 880XP

Page 1: ...ta CA N554P 11 02 NOTE This product is intended for installation by a professional installer only Any attempt to install this product by any person other than a trained professional may result in seve...

Page 2: ...interference and 2 This device must accept any interference received including interference that may cause undesired operation Changes or modifications not expressly approved by the party responsible...

Page 3: ...P Pl lu ug g I In n H Ha ar rn ne es ss s 1 19 9 Super Bright LED 2 Pin WHITE Plug 19 Valet Program Switch 2 Pin BLUE Plug 20 Programmer Interface 3 Pin Port 20 Shock Sensor Harness 4 Pin Connector 20...

Page 4: ...vehicle in gear and 2 Never remotely start the vehicle with the keys in the ignition The user will be responsible for having the neutral safety feature of the vehicle periodically checked wherein the...

Page 5: ...location Remove the domelight fuse This prevents accidentally draining the battery Roll down a window to avoid being locked out of the car Finding the Tachometer Wire To test for a tachometer wire a...

Page 6: ...r multimeter to DCV or DC voltage 12 or 20V is fine 2 Attach the probe of the meter to 12V 3 Probe the wire that you suspect leads to the bulb with the probe of the meter 4 Turn the ignition switch to...

Page 7: ...n accessory such as window automation pager or voice module a 1 Amp diode must be installed to ensure proper operation Insert the diode as shown in the following diagram IMPORTANT Never interrupt any...

Page 8: ...ontrol wires in Toyota Lexus BMW some Mitsubishi some Mazda and other models NOTE For parking light systems that draw 10 amps or more the jumper must be switched to a light flash output See the Progra...

Page 9: ...EN Door Trigger Input Zone 3 and Door Icon Most vehicles use negative door trigger circuits Connect the GREEN wire to a wire showing ground when any door is opened When connecting to newer model vehic...

Page 10: ...type of dome circuit is used in many Ford products Connect the VIOLET wire to a wire that shows 12V when any door is opened This wire will report Zone 3 NOTE If using a door trigger wire that has a de...

Page 11: ...the point you obtain 12V Do not use the 15A fuse in the harness for this purpose This fuse protects the module itself H1 12 RED WHITE 200 mA Output When the system receives the code controlling Chann...

Page 12: ...bulb a relay must be used to change the polarity See Finding the Wait To Start Bulb Wire For Diesels section of this guide Here are some common colors of this wire Chevrolet and GMC trucks Light Blue...

Page 13: ...is output can be programmed to provide the following types of outputs See the Feature Menus section Validity Output that will send a signal as long as the transmission is received Latched Output that...

Page 14: ...e source of current for all the circuits the relay satellite will energize They must be connected to a high current source Since the factory supplies 12V to the key switch that is used to operate the...

Page 15: ...vehicles that do not have a second ignition wire this connection is not required Remote Start Ribbon Harness Wiring Diagram ___ ___ ___ ___ ___ Remote Start Harness H3 Wire Connection Guide Remote Sta...

Page 16: ...anti theft system when the remote start shuts down See the Feature Descriptions section in this guide NOTE This wire can also be used to bypass optional sensors and door triggers as described in the...

Page 17: ...Installation Points to Remember section of this guide for finding the tachometer wire Once connected you must teach the system the tach signal See Tach Learning section of this guide H3 6 BLACK WHITE...

Page 18: ...sure the hood is closed and there are no remote start shut downs active 3 Set the emergency brake 4 Turn the key to the run position this will release the shifter 5 Place the car in drive D 6 Place y...

Page 19: ...Pin WHITE Plug The super bright LED operates at 2 volt DC and plugs into the two pin WHITE port Make sure the LED wires are not shorted to ground as the LED will be damaged Multiple LED s can be used...

Page 20: ...ing of the unit When using the 998T Bitwriter it is possible to configure any and all of the programmable functions For more infor mation please refer to the guide packaged with the programmer This po...

Page 21: ...ted horizontally Metallic window tint can also affect range so this should be a consideration when determining the mounting location After determining the best mounting location follow these steps 1 C...

Page 22: ...the H1 2 light flash output harness wire Tach Threshold On Off In most cases this jumper can be left in the OFF position Some new vehicles use less than 12 volts in their ignition systems The unit ma...

Page 23: ...using the 998T Bitwriter 1 O Op pe en n a a d do oo or r The H1 5 GREEN wire or the H1 7 VIOLET wire must be connected 2 I Ig gn ni it ti io on n Turn the ignition on then back off The heavy gauge PIN...

Page 24: ...menu 1 Press and release the Valet Program switch the number of times necessary to advance from the feature you just programmed to the next one you want to program 2 Then press the Valet Program switc...

Page 25: ...ypass Notification chirp OFF 2 7 Ignition controlled domelight ON Ignition controlled domelight OFF 2 8 Single unlock pulse Double unlock pulse 2 9 Factory disarm with Channel 2 ON Factory disarm with...

Page 26: ...on the doors will lock three seconds after the ignition is turned on and unlock when the ignition is turned off The 998T Bitwriter will display separate steps for ignition lock and ignition unlock Th...

Page 27: ...he ignition is turned off 1 8 AUTOMATIC ENGINE DISABLE AED ON OFF AED is a full time passive starter disable that works independently of the security system When turned on the orange ground when armed...

Page 28: ...or the ignition trigger at any time If NPC is turned off the system will respond to repeated triggers on the sensor inputs and will do so indefinitely Some states have laws regulating how many times...

Page 29: ...icle s tach wire or voltage depending on the programming of feature 3 2 If programmed OFF the vehicle will crank for the programmed crank time feature 3 5 and will not verify with tach or voltage that...

Page 30: ...sed to energize circuits in the vehicle that operate accessories such as the radio or heater 3 8 BLUE WIRE STATUS OUTPUT FACTORY SECURITY RE ARM OUTPUT The blue H3 1 wire will supply a 200mA output fo...

Page 31: ...nnel The unit will chirp indicating successful programming It is not possible to teach a transmitter button to the system more than once 5 R Re el le ea as se e Once the code is learned the Valet Prog...

Page 32: ...hen press it once more and hold it The siren will chirp three times to confirm it is ready to receive the code from the transmitter To exit the learn routine One long horn honk indicates that Learn Ro...

Page 33: ...on When programmed for single button arm disarm configuration the transmitter buttons are assigned to the following functions operates Arm Disarm Panic operates Channel 2 and Silent Mode operates Remo...

Page 34: ...own of the remote start system T To o e en nt te er r d di ia ag gn no os st ti ic c m mo od de e 1 Turn the ignition off 2 Press and hold the Valet program switch 3 Turn the ignition on then off agai...

Page 35: ...escription of NPC operations refer to the owner s manual Rapid Resume Logic Rapid Resume Logic ensures that when the system is powered up it will return to the same state it was in when power is disco...

Page 36: ...or information on which zone is active or has been violated refer to the Table of Zones System Status Chirps Table of Zones NOTE The Warn Away response does not report on the LED but will report on th...

Page 37: ...To access long term event history 1 With the ignition off press and HOLD the Valet Program switch 2 Turn on the ignition 3 Release the Valet Program switch 4 Press and release the Valet Program switch...

Page 38: ...ircuit a Make sure the hood is closed and no other shutdown circuits are active b Set the emergency brake c Turn the ignition key to the run position but do not start the engine d Put the vehicle in D...

Page 39: ...conds That s how the progressive two stage door input works This is a feature of this system This is an instant trigger remember since even if the door is instantly closed again the progression from c...

Page 40: ...es on the relay satellite Also make sure that the ground wire connects to a good chassis ground point Check diagnostics The diagnostics will tell you which shutdown is active or not connected Check th...

Page 41: ...regardless of how long it takes for the vehicle to actually start Adjust to a lower cranking time Was the Tach Learn successful The LED must light solid and bright to indicate a successful learn Make...

Page 42: ...42 2002 Directed Electronics Inc...

Page 43: ...2002 Directed Electronics Inc 43 Wiring Quick Reference Guide...

Page 44: ...44 2002 Directed Electronics Inc...

Reviews: