Diagnostics
The system’s microprocessor monitors and reports all active and violated zones when arming and
disarming. LED flashes indicate the active or violated zone; siren chirps indicate system status.
Arm/Disarm Diagnostics
The number of siren chirps will indicate the status of the system when arming and disarming. For
information on which zone is active or has been violated refer to the
Table of Zones.
System Status Chirps
Table of Zones
NOTE: The Warn Away® response does not report on the LED.
Zone No.
Trigger type
Input description
1
Instant
H1/6 BLUE wire. Connect to optional hood/trunk
pins.
2
Multiplexed
BLUE wire of plug-in shock sensor. Inputs
shorter than 0.8 seconds will trigger a Warning
Zone response, while inputs longer than 0.8
seconds will instantly trigger the full alarm
sequence.
3
Two-stage, progresses from
Door switch circuit. H1/5 GREEN or H1/7 VIOLET.
warning to full alarm
4
Multiplexed Input
GREEN wire of plug-in shock sensor. Inputs
shorter than 0.8 seconds will trigger a Warning
Zone response, while inputs longer than 0.8
seconds will instantly trigger the full alarm
sequence.
5
Two-stage (similar to doors)
Ignition input. H1/9 YELLOW.
Action
Number of Chirps
Description
Arm
1
System armed
Arm
1 (3 second delay), 1
System armed with Bypass Notification
Disarm
2
System disarmed
Disarm
4
System disarmed with Tamper Alert
Disarm
5
System disarmed NPC® active