©
2003
Directed Electronics, Inc.
29
2-7 IGNITION CONTROLLED DOME LIGHT SUPERVISION ON/OFF:
If turned on, the
system will turn on the dome light for 60 seconds when the ignition is turned off. The optional
dome light supervision feature must be installed as described in the Wire Connection Guide.
2-8 DOUBLE PULSE UNLOCK ON/OFF:
Some vehicles require two pulses on a single wire to
unlock the doors. When the double pulse unlock feature is turned on, the BLUE H4/C wire will
supply two negative pulses instead of a single pulse. At the same time, the GREEN H4/A wire will
supply two positive pulses instead of a single pulse. This makes it possible to directly interface with
double pulse vehicles without any extra parts.
2-9 FACTORY ALARM DISARM WITH CHANNEL 2:
In the default setting the factory alarm
disarm output will disarm the factory alarm system any time the button(s) controlling Channel Two
is pressed.
2-10 CHANNEL 4 VALIDITY/LATCHED/LATCHED RESET WITH IGNITION/30 SECOND
TIMED/SECOND UNLOCK OUTPUT:
Channel Four can be programmed for these output
configurations. The unit is set to the default validity output. To change the configuration, use the
two-chirp setting to toggle through the different configurations.
Menu #3 - Renote Start Features
3-1 ENGINE CHECKING ON/OFF:
In the default setting the remote start will monitor either the
vehicle's tach wire or voltage depending on the programming of feature 3-2. If programmed OFF
the vehicle will crank for the programmed crank time (feature 3-5) and will not verify with tach or
voltage that the car is running. In the OFF setting, if the vehicle fails to start, the ignition can stay
on for the entire run duration. Using tach or voltage check is always recommended if possible.
3-2 CHECKING TYPE TACH/VOLTAGE:
Selects the method of engine monitoring. If set to
TACHOMETER the unit will reference the learned tach signal to disengage the starter. In addition
it will monitor the RPM and shut down if the engine RPM is too high or too low. When set to
VOLTAGE, the unit will crank the starter for the programmed time and then attempt to sense that
the engine is running by detecting an increase in voltage. The threshold for the voltage check is
selectable in feature 3-6.
3-3 RUN TIME 12, 24, 60 MINUTES:
Selects the time in minutes that the system will
operate the engine until the system "times out". This is the maximum operation period and
the system may be shut down using a shutdown at any time. Using the 998T Bitwriter, the
run time can be programmed for any duration from 1-60 minutes.
3-4 PARKING LIGHTS FLASHING/CONSTANT:
In the default setting, the unit will flash the
vehicle's parking lights (if connected) while remote started. The constant setting will turn the
parking lights on solid for the entire run duration.
3-5 CRANK TIME 0.6/0.8/1.0/1.2/1.4/1.6/1.8/2.0/4.0 SECONDS:
If the unit is programmed for
no engine checking or voltage sense, the crank time must be set to the appropriate duration. The
default setting is 0.6 second. If a different crank time is desired, select feature 3-5 and select either