background image

L

N

L

L
N

Switch

230V~ 50Hz

L

Load

Switch

L
N

L

N L

Load

230V~ 50Hz

L

- Installation with a Switch for activate or deactivate manually the

  movement detection:

- Installation with a Switch for permanent ON

:

SETTINGS

"Lux" and "Time" values can be adjusted via its control knobs.
Lux Settings:

· This setting allows to select the minimum level of natural light in wich the

  detector would detect movement. In case it detects movement and natural

  light is below the indicated level, the device will not respond.

· The user can set this value between 3 and 100 Lux. 

· If the detector is expected to work despite of surrounding natural light, set

  the potentiometer in "        ".

· On the contrary, if you want the detector to work only at night (without any

  natural light), set the potentiometer on “    ”.

Time Settings:

· This setting allows to select the span of time during which lamps will remain

  on, after movement detection.

· Timing starts whenever movement is detected.

· This time can be set between 6sec and 12min.

6

SETTINGS AND TEST

TESTING PROCESS

The purpose of the test procedure is to check and adjust the coverage

pattern of the motion sensor when it is connected for the first time. 

             Once it is powered, the detector needs ~2 minutes for
initialization. Then it will start operating normally.  

8

PROBLEM SOLVING

Lamp does not

light up

1. Power is not turned on
2. Wrong wiring
3. Incorrect setting of Lux
4. Lamp may be defect

1. Supply the detector
2. Check connections
3. Check this setting
4. Replace lamp

Lamp stays on

continuously

1. Time delay setting too high
2. Heat activity detected within

    detection area

3. Wrong wiring

1. Decrease the timing
2. Keep away from the coverage

    area and remove movement

    sources (animals, fans,

    airstream, etc)
3. Check connections

Lamp is

switched on/off

cyclically

The load (fluorescence,

contactor,...) is continuously

generating harmonics triggering

the detector in each switching

Keep away the detector from

the load or connect a RC

harmonic suppression filter

between L’ and N

Nuisance

triggering

Heat sources, highly reflective

objects or any object which may

be swayed by the wind is within

the detection range

Avoid aiming the detector

towards any heat source, any

reflective surface or swaying

objects

7

MASKING CLIPS

DINUY S.A.

c/Auzolan Nº2

20303 Irún (Spain)

[email protected]

www.dinuy.com

The red LED which is within the lens can be used as an indicator when

performing the testing process without any load. This LED lights whenever

motion is detected and stays on until the time delay expires.
Process:

 · Set the “Lux” potentometer on “         ” and “Time” in the minimum. 

 · Walk towards the coverage area. Once it detects movement, the LED as

    well as the lamps will be lit for 6 seconds.

When the detector stops working, check the possible failures and the

solutions suggested in the following table that maybe will help you to solve

the problem:

There are three covers available to restrict the coverage area.

To fix the restriction covers, the decorative frame has a slot on its rear side,

where the projection of the cover fits.

Problem

Possible cause

Suggested solution

LUX

TIME

Note

.

Reviews: