L
N
L
N L
Load
230V~ 50Hz
L
L
N
L
N L
Load
L
N L
230V~ 50Hz
L
L
INSTRUCTIONS MANUAL
Technical Specifications
• Power supply: 230V
AC
±10% ~50 Hz
• Power consumption: <1W
• Load: 10A cosφ= 1
- LED lamps: 200W
- Incandescence: 2.000W
- 230V Halogens: 2.000W
- LV Halogen with Electronic transfo: 2.000W
- LV Halogen with Ferromagnetic transfo: 1.600W
- Fluorescence:600W (100µF)
• Coverage: 360º, max. Ø7 at 2,5m high and 18ºC
• Settings: Via Potentiometer
• Level of luminosity: 3 ~ 100Lux
• Timing: 6 seconds ~ 12 minutes
• Environmental protection: IP40, Class II
• Operating temperature: –10ºC ~ +45ºC
1
DESCRIPTION
• Indoor motion detector for flush-ceiling mounting.
• Focus type assembly allows its installation in ceilings with different
thickness.
• Circular detection area, 360º
• One switching no-free-voltage output.
• High capacity relay with “zero crossing” control, which allows switching
practically any type of load.
• Natural light measurement, allowing condition its operation to daylight level.
• High sensitivity PIR sensor, which detects very small movements.
• Possibility to connect several detectors in parallel to expand the area to be
covered in a single line of lighting.
3
INSTALLATION
The optimal height for its assembly is 2,5m, which can cover up to Ø7m.
A. Setting the device:
Given that the sensor responds to movement and to heat, avoid the following
situations:
· Pointing the detector towards objects with reflective surfaces such as
mirrors.
· Positioning the sensor near heat sources such as ventilation systems, air
conditioning devices or lamps.
· Pointing te detector towards objects which could be moved by draughts,
such as curtains, plants...
Take into account the walking direction when installing. It is less sensitive to
movement across the detector and more sensitive to movement directly
toward the sensor, which will reduce the detection coverage.
CAUTION
2
DIMENSIONS
4
RANGE
5
WIRING DIAGRAMS
B. Mounting:
Drill a hole of Ø65mm in the ceiling:
Make the wiring connections following the installation diagrams and set the
desired values of Lux and Time.
- Simple installation:
- Installation of 2 detectors in parallel:
• Installation of electric equipment must be carried out by qualified
professionals.
• Before you start making any connections, disconnect the power supply
to avoid any risk.
• When some kinds of lamps blow, they can produce a very high current
which could damage the detector.
63,5mm
45mm
80mm
63,5mm
Walking across:
More sensitive
Walking towards:
Less sensitive
Ø
3m
Ø
7m
2,5m
FLUSH-CEILING MOUNTED
MOTION DETECTOR
1 Channel / 10A
DM TEC 008