background image

L

N

L

N L

Load

230V~ 50Hz

L

L
N

L

N L

Load

L

N L

230V~ 50Hz

L

L

INSTRUCTIONS MANUAL

Technical Specifications

• Power supply: 230V

AC

 ±10% ~50 Hz

• Power consumption: <1W
• Load: 10A cosφ= 1

     - LED lamps: 200W 

     - Incandescence: 2.000W

     - 230V Halogens: 2.000W

     - LV Halogen with Electronic transfo: 2.000W

     - LV Halogen with Ferromagnetic transfo: 1.600W

     - Fluorescence:600W (100µF)
• Coverage: 360º, max. Ø7 at 2,5m high and 18ºC
• Settings: Via Potentiometer 
• Level of luminosity: 3 ~ 100Lux
• Timing: 6 seconds ~ 12 minutes
• Environmental protection: IP40, Class II
• Operating temperature: –10ºC ~ +45ºC

1

DESCRIPTION

•  Indoor motion detector for flush-ceiling mounting.

•  Focus type assembly allows its installation in ceilings with different

   thickness.

•  Circular detection area, 360º

•  One switching no-free-voltage output.

•  High capacity relay with “zero crossing” control, which allows switching

   practically any type of load.

•  Natural light measurement, allowing condition its operation to daylight level. 

•  High sensitivity PIR sensor, which detects very small movements.

•  Possibility to connect several detectors in parallel to expand the area to be

   covered in a single line of lighting. 

3

INSTALLATION

The optimal height for its assembly is 2,5m, which can cover up to Ø7m.

A. Setting the device:
Given that the sensor responds to movement and to heat, avoid the following

situations:  

· Pointing the detector towards objects with reflective surfaces such as

  mirrors. 

· Positioning the sensor near heat sources such as ventilation systems, air

  conditioning devices or lamps. 

· Pointing te detector towards objects which could be moved by draughts,

  such as curtains, plants...
Take into account the walking direction when installing. It is less sensitive to

movement across the detector and more sensitive to movement directly

toward the sensor, which will reduce the detection coverage.

CAUTION

2

DIMENSIONS

4

RANGE

5

WIRING DIAGRAMS

B. Mounting:

Drill a hole of Ø65mm in the ceiling: 

Make the wiring connections following the installation diagrams and set the

desired values of Lux and Time.

   - Simple installation:

- Installation of 2 detectors in parallel:

• Installation of electric equipment must be carried out by qualified

  professionals.
• Before you start making any connections, disconnect the power supply

  to avoid any risk.
• When some kinds of lamps blow, they can produce a very high current

  which could damage the detector. 

63,5mm

45mm

80mm

63,5mm

Walking across:

More sensitive

Walking towards:

Less sensitive

Ø

3m

Ø

7m

2,5m

FLUSH-CEILING MOUNTED

MOTION DETECTOR

1 Channel / 10A

DM TEC 008