background image

E94HDI31.FH11   Thu May 03 11:48:00 2007      Page 2     

Composite

C

M

Y

CM

MY

CY CMY

K

1. Aim the detector to the area we want to cover.

2. Turn power on.

3. Warm up the detector for at least 30 seconds.

4. Have someone walk across the pattern from outside of

    coverage until detection is made.

5. Adjust the detector head if needed to change the coverage

    zone.

6. Repeat steps 4 and 5 until detection coverage zone meets

    your requirement.

This motion detector will send an RF codified signal in case

of detection. The red led inside will shine.

These motion detectors can be associated to different

receivers (Timer, staircase activator). The codification is

composed by two parts, one in the detector and a second

one associated to the receiver explained in the receiver’s

instruction manual.

In order to allow the receiver to learn the code from the

detector, these steps must be followed:

1)  Install the batteries.

2)  Place the switch in ON position.

3 The motion detector sends a signal to the receiver.

4)  Switch off the codified detector by placing the switch in

                       OFF position to avoid interferences if more detectors

                       must be codified.

5) Once all the detectors are codified, please place the

                       switch of all the detectors in ON position for the normal

                       operation.

D. Procedure of Walk Test.

4

WALK AND TEST

ADJUSTEMENT

C. Normal working.

5

CODIFYING THE

DETECTORS

E. Lux potentiometer. Lighting adjustment.

- In case you want to cancel this function, please place

  this potentiometer in the maximum value so the

  motion detector will send the signal always.

6

LOW BATTERIES

When the batteries are low the red led on the detector

will blink permanently until the batteries are replaced

by new ones.

LED

A. Batteries installation.

3 units 1,5 volts batteries LR03 AA type (not included).

B. ON-OFF Switch.

- A minimum level of luxes can be adjusted. Over that lux

  value the detector will not work. Only if the ambience

  light level is down that value, the detector will send the

  signal.

- This adjusting is made with the LUX potentiometer.

Signed:

Andoni Asurmendi García

Managing director

The declarant: ANDONI ASURMENDI GARCIA, as MANAGING

DIRECTOR, of Dinuy S. A., placed in: Calle Auzolan nº2.

Tel34 943 627988  Fax:+34 943 625764

E-Mail: [email protected]  D.N.I.:15.238.733
Declares, under its own responsibility that the equipment:

WIRE FREE PIR MOVEMENT DETECTOR.

SURFACE MOUNTING

manufactured by: DINUY, S.A. in SPAIN; brand DINUY;

model DM SEN R02 are manufactured according to the Low Tension

Directive (73/23EEC, modified by the 93/68EEC), to the

Electromagnetic Compatibility Directive (89/336/EEC, modified by the

92/31/CEE and the 93/68/CEE) and to the Directive 1999/5/EC for

radioelectric equipments and for telecommunication terminals

equipments and its mutual conformity acknowledgment.

For this purpose the following harmonised Norms have been applied:

ETSI EN 300220-1 V1.3.1 (2.000-09)

ETS 300683 (1997)

EN 60950

And the following technical reports have been achieved:

LABEIN Nº B034/03-36-EE-R1

LABEIN Nº B034/03-36-EE-E1

LABEIN Nº B034/03-36-EE-B1

DECLARATION OF CONFORMITY CE

Irun 2007-05-03

Reviews: