IPG2160 IPG2320 GSM 2G VoIP Gateway User Manual
_______________________________________________________________________________
10
‘dial the extension number’, press *158# on mobile phone then local IP address will be reported
by gateway automatically.
3.2.2 Restore factory setting via IVR
With a Mobile phone call the SIM card number, the gateway will answer and play voice prompt
‘dial the extension number’, press *166*000000# on mobile phone then the user will hear
‘setting succeed’. Reboot gateway to take setting effective.
3.2.3 Restore default IP and password
Press RST button about 3 seconds then reboot gateway. The IP address, username and
password will be back to factory default.
3.2.4 Restore factory setting
Press RST button about 7 seconds then reboot gateway then it will restore to factory setting.
3.2.5 Console port access
The gateway provide Console port for maintenance purpose. It adopts RS232 standards with
band rate 115200bps.
4. WEB Interface Configuration
IPG2160 IPG2320 serials gateway has the same web interface. This charpter describes web
configuration of IPG2160 IPG2320. The IPG2160 IPG2320 contains an embedded web server
to set parameters by using the HTTP protocol. We are strongly recommend to access device
with
Google Chrome or Firefox Browser.
The configuration introduction also suitable for following models:
IPG2160 IPG2320
IPG2041
IPG2081
4.1 Access IPG2160 IPG2320 unit
Enter IP address of IPG2160 IPG2320 in IE/Google Chrome. The default IP of LAN port is
192.168.11.1. and the GUI shows as below:
Figure 4-1-1 WEB log interface