50
Operating instructions • DINO 105TL
7.1. SCHEDULE FOR INSPECTIONS REQUIRED BY THE AUTHORITIES
The inspections must be performed in accordance with local and national regulations,
in accordance with the legislation and standards.
The lift must be subjected to a
start-up inspection
before it is used for the first time and
before starting it up the first time after a major repair or modification work.
The lift must be subjected to a thorough
periodic inspection
with related
test loading
at
intervals of one year.
The inspection must be carried out within twelve (12) months of the first inspection or
previous regular inspection.
In connection with the periodic inspection the lift must be subjected to a
non-destructive
inspection/inspection disassembled
in general at intervals of ten (10) years from the start-
up date.
In addition, the lift much be
inspected
to the extent applicable after any exceptional situation
The inspections of the lift must be carried out at regular intervals as long as it is in use.
If the lift is used under extreme conditions, intervals between the inspections shall be
reduced.
The overall operating condition of the lift as well as the condition of the safety-related control
devices shall be established in the regular inspections. Particular attention shall be paid to
changes, which affect the operational safety.
In connection with the regular inspection shall be established to what extent the lessons and
practical experience gained since the previous inspection could be utilized to improve the
safety even more.
For the inspection must be assigned an
expert inspection body
with
documented
evidence of competence
or an
expert with documented evidence of competence
.
A
protocol
must be drawn up of the executed inspections. The protocols of the start-up
and periodic inspections must be kept with the lift or its immediate proximity for at least five
years.
DANGER
WARNING
CAUTION
NOTICE
Check the regulations for the inspections and the competence of the inspector with
the local authorities.
Summary of Contents for 10196
Page 2: ......
Page 3: ...3 TRANSLATION OF THE ORIGINAL INSTRUCTIONS Valid from serial number 105TL 10196...
Page 6: ...6 Operating instructions DINO 105TL BLANK...
Page 10: ...10 Operating instructions DINO 105TL 2 1 DIMENSION DRAWING...
Page 46: ...46 Operating instructions DINO 105TL NOTES...
Page 47: ...47 NOTES...
Page 51: ...51 7 2 LUBRICATION PLAN 5 8 6 10 7 5 4 2 1 11 3 9 12...
Page 55: ...55 BLANK...
Page 56: ...56 Operating instructions DINO 105TL BLANK...
Page 58: ...58 Operating instructions DINO 105TL NOTES...
Page 59: ...59 NOTES...