Dini Argeo 6116PRO Use Instructions Download Page 20

6116PRO

Optimized layout for A4 print.

20

USER_MAN_ENG_6116PRO

In order to update the AF Firmwares loaded on the indicator, save the files provided by the reseller/supplier on a USB key and press 
the updating button (see "

H

" button in the main screen, described on page 15).

On the display, a screen with a list of updated firmwares will be shown:

Updating AF Firmwares

Summary of Contents for 6116PRO

Page 1: ...6116PRO www diniargeo com Industrial touch screen PC with integrated scale input ENGLISH USE INSTRUCTIONS...

Page 2: ......

Page 3: ...a DINI ARGEO product 6116PRO is the new high performance PC made in stainless steel designed to meet the most advanced weighing needs Intel computing power together with Dini Argeo electronics and we...

Page 4: ...al pipes Cables connecting load cells and any external device must be as short as possible Cable ends connectors conductors terminals etc must be installed up to standard the cable shielding must be k...

Page 5: ...r analogue digital signals 25V sensors load cells Low tension power supply cables 60V Coaxial cables DC power supply cables with voltage 60V and 400V AC power supply cables with voltage 25V and 400V P...

Page 6: ...ts the upper part with the lower part of the load cell through a copper braid section not less than 16 mm the upper part must be short circuited with the surface of the weighing structure and the lowe...

Page 7: ...7 6116PRO Optimized layout for A4 print ON OFF Button Main switch I 0 USER_MAN_ENG_6116PRO Wiring diagram...

Page 8: ...ty and pressure 6 PC support structure 7 Fastening slots 8 Hole for cable passage POS DESCRIPTION 9 Connection to load cell cable 10 Connection to power cable 11 ON OFF switch 12 Slot for DGT weight i...

Page 9: ...9 6116PRO Optimized layout for A4 print USER_MAN_ENG_6116PRO The following dimensions are shown in mm Dimensional technical drawing...

Page 10: ...ssure Scale input Max 10 000e or multi range 2 x 3000e 0 3 V d in CE M approved version for legal trade use Max 1 000 000d displayable with an internal resolution up to 3 000 000 points Up to 8 signal...

Page 11: ...000 10 000 10 000 100 AF02 Articles database Clients database Tares database Input texts 10 000 10 000 10 000 100 AF03 Clients database Suppliers database Materials database Vehicles database Badges d...

Page 12: ...mized layout for A4 print 12 USER_MAN_ENG_6116PRO Touch screen calibration 1 Run the application TBCALIB from the toolbar 2 Insert Password 3 Press and hold the centre of the crosses until the circle...

Page 13: ...ed by following the file path C DiniArgeo Dini Simulator Configuration scripts ATTENTION This procedure is not reversible The software Launcher will be started by means of the link on the desktop In o...

Page 14: ...below for detailed dimensions which are shown in mm 3 Let the cable pass through the related hole C 4 Wall mount the industrial PC by means of screws D screw and dowel sizes which are at the customer...

Page 15: ...s the Windows software File Explorer C Task manager It opens the Windows software Task manager D Remote assistance It opens the software Teamviewer for remote assistance E Arrows They scroll the appli...

Page 16: ...in the folder C Dini Argeo Dini Simulator Firmwares Tools In order to add a software protected by a password to the bar it is necessary to create a connection to the EXE file in the folder C Dini Arge...

Page 17: ...ile in which all the weighings are saved on USB and SD card They can be accessed by following the file path C Dini Argeo Shared 6116 It is possible to export these files to external folders and suppor...

Page 18: ...ptimized layout for A4 print 18 C D E F USER_MAN_ENG_6116PRO 3 Press Printout button C for accessing the print functions 4 Press arrow D for accessing the second page 2 2 and select the export functio...

Page 19: ...llowing picture illustrates the dialog box which appears while pressing the OFF button on the structure of the industrial PC on the lower left side Turning off and restart POS DESCRIPTION A It cancels...

Page 20: ...the AF Firmwares loaded on the indicator save the files provided by the reseller supplier on a USB key and press the updating button see H button in the main screen described on page 15 On the displa...

Page 21: ...C 0 8A 50 60 Hz Dini Argeo V Fisica 20 41042 Fiorano MO Italy USER_MAN_ENG_6116PRO The declaration of conformity can be dowloaded from the link http www diniargeo it download aspx by inserting the ser...

Page 22: ...ations to its own products at any moment without notice and without any sanction It is therefore suggested to always verify possible updates The person responsible for the use of the weight indicator...

Page 23: ......

Page 24: ...ax 39 0536 926654 www diniargeo com The information in this document is approximate and can be subject to variations without prior notice by Dini Argeo with respect of the norms in force The official...

Reviews: