15.4.4 DOSAGE
By selecting this functioning mode the output is enabled when the dosage is started and it is disabled when the dosage
ends (see section 13.1).
15.4.5 DOSAGE TARGET
By selecting this functioning mode the output is enabled when the totalised weight reaches the value set for the dosage end
by weight, therefore after the dosage end. The output is disabled by manually disabling the cycle.
15.4.6 PAUSE
By selecting this functioning mode the output is enabled when the dosage is paused, and it is disabled when the dosage
restarts.
15.4.7 MAX.FL.R AND MIN.FL.R
By selecting on of this functioning modes, the output is enabled when the flow is respectively greater than the
the value set in the
<<F.R.ERR.>>
step
or
less than the TARGET - the value set in the
<<F.R.ERR.>>
step.
15.4.8 ALARM
By selecting this functioning mode the output is enabled when a generic alarm is activate.
15.4.9 LOCK
By selecting this functioning mode the output is enabled when time set in the FILL LOCK TIME step
<<LOK.TIM>>
.
15.4.10 WEIGHT PULSE
By selecting this functioning mode the output is enabled when is reached a weight value set in the setup).
15.4.11 FILLING ENABLED
By selecting this functioning mode the output is enabled when the system is in the filling status.
15.4.12 MATERIAL ENABLED
Enabling of the relay:
- on the active dosage;
Disabling of the relay:
- In the dosage by a weight it disabled the relay at TARGET WEIGHT – FLY WEIGHT.
- In the dosage by a time, it disabled the relay at the time set for the dosage.
Manually ending the dosage, through the START/STOP input of the dosage.
15.4.13 LOW FLOW RATE
By selecting this functioning mode the output is enabled when the flow rate is lower than the set value ( in article database).