2.6 Completion 

 

To complete progamming press 

. You can 

also simply hang up. The TFS will 
automatically  break off the connection after  
30 sec.. 

 

To end the connection

 

press “# 0”

 

 

3. Manual switching 

The switch position of the relay, and thus the 
type of operation of the connected 
regulator/thermostat, can be changed manually 
by pressing the key "manual switching". This is 
not possible as long as there is a telephone 
connection. 
 

 

1

 

2

 

3

 

4

manual

 

switching

 

 

 

4. Loading default values 

By pressing the reset key (e.g. with a paper 
clip) it is possible to return the TFS to the 
factory settings. The control light blinks three 
times to show that the TFS was loaded with 
the following default values: 

1) Number of rings: 

2) Access code: 

1234 

3) Relay contacts: 

open 

 

 

5. Operation with an answering 
machine 

If you use the TFS together with an answering 
machine, please proceed as follows to 
establish a connection to the TFS. 

1.  Make sure the TFS is without power, 

otherwise the alteration will not be 
effective. 

2.  Put the switch on the back of the TFS into 

the "on" position. 

3.  Make sure that the number of rings to pick 

up the line is higher for the TFS than for 
your answering machine. 

4.  Dial your telephone number and hang up 

after the first ring. 

5.  Wait 10 sec. (max. 30 sec.) and call again. 

6.  If the call back takes place within max.      

30 sec. the TFS will pick up after the first 
ring. 

 

6. Display 

The TFS has 8 display LEDs for diagnosing 
the system. 
 
 Power 

on. 

 

Blinks by incoming call.  

TFS is occupying the telephone 
line. 

 

Blinks three times after 
successful reset 

Manual 

Displays the switch position, 

switching: 

lights up when the regulator is in 
heating operation (contact 
closed). 
 

 

1

2

3

4

 

manual

switching

 

 

7. Telephone connection 

The TFS has two 6-pole RJ11 (Western) 
telephone slots. However, for the connection of 
the TFS only the slot marked "Line" is needed. 
This slot is connected to the slot for additional 
devices on the telephone jack by means of the 
enclosed connecting cable and the adapter 
plug. 
Please make sure that your telephone jack has 
a slot for additional devices (Germany NFN 
code), so that you can use your telephone and 
the TFS at one jack. 
 

 

1

 

2

3

4

3 4

1

2

3

4

5

6

Line

at theTFS

Adapter plug

Connecting cable

 

RJ11

 TAE (D)

 TST (A)

 

 

8. Technical details 

Power supply:     Power plug  9V~, 0,2A 
Switching power: 10(5) A, 30V 
Protection class   III (low voltage protection) 
 

CC/V

   

 0903

    

   

 6

.6701

.413-01

  Prin

ted in

 German

 Rig

hts re

ser

ved

 to

 ma

ke a

lter

ation

s  

CTY TNHH THI

T B

 NHI

Đ

ÌNH H

I-DHE 

VP: 189 Lý Th

ườ

ng Ki

t, P.6, Q.Tân Bình, TP HCM, VI

T NAM 

Tel: +84 (08) 3863 7722 # Fax: +84 (08) 3865 1859 

URL: www.dinhhai.com - Email: [email protected] 

Reviews: