2.6 Completion
To complete progamming press
. You can
also simply hang up. The TFS will
automatically break off the connection after
30 sec..
To end the connection
press “# 0”
3. Manual switching
The switch position of the relay, and thus the
type of operation of the connected
regulator/thermostat, can be changed manually
by pressing the key "manual switching". This is
not possible as long as there is a telephone
connection.
1
2
3
4
manual
switching
4. Loading default values
By pressing the reset key (e.g. with a paper
clip) it is possible to return the TFS to the
factory settings. The control light blinks three
times to show that the TFS was loaded with
the following default values:
1) Number of rings:
4
2) Access code:
1234
3) Relay contacts:
open
5. Operation with an answering
machine
If you use the TFS together with an answering
machine, please proceed as follows to
establish a connection to the TFS.
1. Make sure the TFS is without power,
otherwise the alteration will not be
effective.
2. Put the switch on the back of the TFS into
the "on" position.
3. Make sure that the number of rings to pick
up the line is higher for the TFS than for
your answering machine.
4. Dial your telephone number and hang up
after the first ring.
5. Wait 10 sec. (max. 30 sec.) and call again.
6. If the call back takes place within max.
30 sec. the TFS will pick up after the first
ring.
6. Display
The TFS has 8 display LEDs for diagnosing
the system.
Power
on.
Blinks by incoming call.
TFS is occupying the telephone
line.
Blinks three times after
successful reset
Manual
Displays the switch position,
switching:
lights up when the regulator is in
heating operation (contact
closed).
1
2
3
4
manual
switching
7. Telephone connection
The TFS has two 6-pole RJ11 (Western)
telephone slots. However, for the connection of
the TFS only the slot marked "Line" is needed.
This slot is connected to the slot for additional
devices on the telephone jack by means of the
enclosed connecting cable and the adapter
plug.
Please make sure that your telephone jack has
a slot for additional devices (Germany NFN
code), so that you can use your telephone and
the TFS at one jack.
1
2
3
4
3 4
1
2
3
4
5
6
Line
at theTFS
Adapter plug
Connecting cable
RJ11
TAE (D)
TST (A)
8. Technical details
Power supply: Power plug 9V~, 0,2A
Switching power: 10(5) A, 30V
Protection class III (low voltage protection)
CC/V
0903
6
.6701
.413-01
Prin
ted in
German
y
Rig
hts re
ser
ved
to
ma
ke a
lter
ation
s
CTY TNHH THI
Ế
T B
Ị
NHI
Ệ
T
Đ
ÌNH H
Ả
I-DHE
VP: 189 Lý Th
ườ
ng Ki
ệ
t, P.6, Q.Tân Bình, TP HCM, VI
Ệ
T NAM
Tel: +84 (08) 3863 7722 # Fax: +84 (08) 3865 1859
URL: www.dinhhai.com - Email: [email protected]