terminal only can resend the connection to the center.

9,The host terminal output control mode settings

Set the output control mode.

There are two ways: oil control mode and the speed control hint mode, the terminal default
oil way

StrValu: the setting value is Ascall code, no fixed length.

When set to "CARON", it can activate the over speed hint way, when the over speed alarm
open, it would output the signal hint. The red line of the terminal would connect with the
alarm speaker or buzzer.
When set to "CAROFF", it can activate the oil way, it means the monitoring center would
send “cut off the oil” instructions, it would use terminal to control the output signal to cut off
the oil way of the car.

11, Short message debugging ways settings

In order to take easy way to debug the terminal and testing the terminal’s working state, the
terminal increase the short message debugging instructions. When you using text messages
to read parameters, you don’t need not to input password, but if you want to change the
machine parameters you have to input the correct password.

Control

1, Remote restart

When the monitoring center remote send the restart instructions, the terminal will
automatically cut off the power and to restart. The directive is mainly used for
communications in normal condition and other abnormal condition, it would cut off the power
of terminal and restart. In order to ensure the terminal can work normally. After restart the
terminal, the mileage statistics will reset

2, Remote controlling oil

This function mainly divided into cut off the oil and supply the oil

The monitoring center allots stop oil instructions, terminal will directly cut off the oil of the
vehicles, the car will shut down.

The monitoring center send the supply oil instructions, the terminal will supply the oil of the
vehicles.

3, Driving mileage initialization

Set the designated vehicles mileage

Miles: 3 bytes, show HEX, the unit is meters, range: 0 ~ 0 xFFFFFF x000000 such as 0

Summary of Contents for A300

Page 1: ...o Ltd Tel 86 10 52679667 57430056 http www dingtek com E mail gps dingtek com Room 605 Building Botai B Nanhudongyuan 122 Chaoyang District Beijing China 100102 Page 1 GPS Vehicle Tracker A300 User manual Version V1 3 Date 2012 09 05 ...

Page 2: ...d Tel 86 10 52679667 57430056 http www dingtek com E mail gps dingtek com Room 605 Building Botai B Nanhudongyuan 122 Chaoyang District Beijing China 100102 Page 2 Index Query function 3 Settings 3 Control 5 Alarm 6 Other 7 wire diagram 8 ...

Page 3: ...on software release time Settings 1 Fixed time set times to return position information settings Set designated vehicles according to the fixed time times to send the location information to the center through UDP This instruction request the terminal use interval as the time interval return location information up to 65535 times positioning information 2 Fixed time return location information s t...

Page 4: ...d restrict the vehicles only can drive in the permitted line range At present it only support 1 line node 6 IP and port setting The monitoring center can change the terminal IP number and port number at any time After you change the terminal the new IP and port number would take effect immediately After you changed the IP port the terminal would reply response information to the original IP port a...

Page 5: ...minal and testing the terminal s working state the terminal increase the short message debugging instructions When you using text messages to read parameters you don t need not to input password but if you want to change the machine parameters you have to input the correct password Control 1 Remote restart When the monitoring center remote send the restart instructions the terminal will automatica...

Page 6: ...ld upload a message The rest alarm would according to the scheduled time resending time s interval to upload the message Cancel alarm way You should send the cancelling alarm instructions to the terminal and the vehicles running speed is smaller than overspeed alarm witnesses value Send the cancelling overspeed instructions and close the overspeed alarm 2 Parking overtime alarm valve setting After...

Page 7: ...ht stays on when cancel the alarm the button s light off Alarm way When the fist alarm it would upload a message It is according to time interval to upload the message Cancel alarm way The monitoring center send the calcelling alarm instructions 7 Geo fence alarm After you set up the Geo fence when you run in and out of the fence the terminal would upload a hint information Alarm way Triggered ala...

Page 8: ...eijing China 100102 Page 8 5 SMS or platform remote inquires the terminal parameters You can check the terminal s parameter configuration through SMS or GPRS instruciton These parameter configurations include parameters of the terminal such as TCP UDP the terminal code resending time APN Error record etc wire diagram Main Main Main Main I O I O I O I O port port port port ...

Page 9: ...n 7 Orange SoS button Pin 8 Purple Oil cut Pin 9 10 Reserved RS232 RS232 RS232 RS232 port port port port Pin 1 RX 232 Pin 2 TX 232 Pin 3 GND Pin 4 5V output Connected with Z100 cement drum sensor Tracker RS232 Pin 3 GND Z100 Blue line GND Tracker RS232 Pin 4 5V output Z100 Brown line VCC Tracker IO port Pin 4 Brown Green Z100 Black line Connect with Temperature Box Tracker RS232 pin x Temperature ...

Page 10: ... Solution check whether GPS antenna covered by some metal objects whether the copper coil of the port break off 3 GPS module broken the lights keeps lighting off Reasons The lights tube broken GPS module broken suggest return the terminal to factory for repairing GSM light red 1 GPRS connect to the center successfully 0 5 seconds light on off light flashing quickly 2 SIM card register GPRS failed ...

Reviews: