OPERATOR’S MANUAL
with Maintenance Information
Maintenance
63
B-3
Inspect the Tires and Wheels
(including castle nut torque)
DINGLI requires that this procedure be
performed every 250 hours or quarterly,
whichever comes first.
Maintaining the tires and wheels in good
condition is essential to safe operation and
good performance. Tire and/or wheel failure
could result in a machine tip-over. Component
damage may also result if problems are not
discovered and repaired in a timely fashion.
1 Check the tire surface and sidewalls for
cuts, cracks, punctures and unusual wear.
2 Check each wheel for damage, bends and
cracks.
For HD model machine
3 Remove the cotter pin and check each
castle nut for proper torque.
Note: Always replace the cotter pin with a new
one when removing the castle nut or when
checking the torque of the castle nut.
4 Install a new cotter pin. Bend the cotter pin
to lock it in place.
Castle nut torque, dry
406.7Nm
Castle nut torque, lubricated
305Nm
For DC model machine
3 Check each bolt for proper torque.
Bolt torque, dry
88Nm
Bolt torque, lubricated
66Nm
B-4
Test the Emergency Stop
DINGLI requires that this procedure be
performed every 250 hours or quarterly,
whichever comes first.
A properly functioning Emergency Stop is
essential for safe machine operation. An
improperly operating red Emergency Stop
button will fail to shut off power and stop all
machine functions, resulting in a hazardous
situation.
As a safety feature, selecting and operating
the ground controls will override the platform
controls, except the platform red Emergency
Stop button.
1 Turn the key switch to ground control. Turn
the ground red Emergency Stop button
clockwise to the on position. Pull out the
platform red Emergency Stop button to the
on position.
2 Push in the red Emergency Stop button at
the ground controls to the off position.
⊙
Result: No machine functions should
operate.
3 Turn the key switch to platform control.
Turn the ground red Emergency Stop
button clockwise to the on position. Pull
out the
platform red Emergency Stop
button to the on position.
4 Push in the red Emergency Stop button at
the platform controls to the off position.
⊙
Result: No machine functions should
operate.
Note: The red Emergency Stop button at the
ground controls will stop all machine operation,
even if the key switch is switched to platform
control.