dimtel
dimtel
5.3
Display Panels
Figure 12: Environmental monitoring panel
The iGp-5120F can continue operating with the main chassis fan stopped,
however such operation puts high stress on certain key semiconductor devices.
Prolonged operation without main chassis fan should be avoided.
5.3.9
Device Controls Panel
Device controls panel provides control interface to several peripherals inte-
grated in the iGp-5120F. There are four adjustable delay units for controlling
the high-speed ADC, DAC, and fiducial timing.
WARNING: While these delay controls can be used to adjust var-
ious clock timings, one is strongly advised to perform the adjust-
ments via the timing panel. Timing panel controls interface to a
sophisticated IOC routine which in turn computes the necessary
settings of the four delay units.
In addition to delay devices this panel provides controls for the low-speed
eight channel DAC. Channels 0 though 6 are brought out on the front-panel
29 of 58