Procedure
Release the front cover from the unit by
undoing the two screws under
the bottom edge.
Carefully remove cover by pulling bottom-front forward, and then lift to
release top from retaining slots.
Mark screw fixing positions on wall in accordance with the dimensions
shown on the diagram in
Fig. 2
. The unit must be secured to the wall
with four screws through the holes provided. The two upper holes are
keyhole shaped to enable the two upper screws to be positioned first.
The unit can then be hung on these screws while the two lower screws
are positioned. Before finally tightening all four screws, ensure the unit
is truly horizontal.
Fit a 3 core 1.5 square millimetre flexible cord through the cable entry
bush, connect wires to the appropriate terminals and tighten cable
clamp. Alternatively the heater may be connected with conduit through
the base after removing the knockout containing the cable entry bush -
see
Fig. 3
.
Wiring Diagram
- see
Fig. 3
Component
A.
Cross Flow Fan
B.
Heat Element
C.
Cut-Out
D.
Electronic Stat
E.
Temperature Selector
F.
Digital Timer
G.
Double Pole Switch
H.
Tri-Clamp T/Block
J.
Cable Clamp
K.
Thermistor
L.
Capacitor
Operation
The WFE3TN has a total loading of 3KW. It
incorporates a sensitive electronic thermostat,
and a programmable 7 day timer. To switch the
appliance ON, it should be connected to the
electricity supply and switched on at the ON/
OFF double pole switch – see ‘b’ in
Fig. 4
.
Thermostat
(see ‘a’ in
Fig. 4
)
The thermostat scale is calibrated in 1°C
divisions with a temperature range from 5°C to
30°C.
To control the room temperature, set the mark
on the thermostat knob to the required
temperature on the scale. The electronic sensor
will monitor continuously the temperature of the
air returning to the inlet grille, and the appropriate
heater element(s) will be selected automatically
to achieve or maintain the chosen level. Two
pilot lights (see ‘d’ in
Fig. 4
)
indicate when one
or both heating elements are in operation. An
additional pilot light on the digital timer will
illuminate when the timer is in ‘Manual On’ mode
or in ‘Auto’ mode with a program running. The
extra sensitivity of the electronic thermostat
ensures that the room temperature is maintained
within close tolerances efficiently and
economically.
2KW NEON
1KW NEON
ON
3
3
N
1
1
2
2
4
4
A
C
E
M
2KW
1KW
1
6
1
6
7
6
8
9
5
B
D
E
F
G
H
J
K
L
Fig. 3
Fig. 4
Fig. 5
Digital Timer Operation
- see
Fig. 6
IMPORTANT: DO NOT plug in the appliance where the load
exceeds 16 Amp.
Mode Selection
There are four different operating modes. Press MODE to cycle through
these:
MAN OFF –
heat is permanently off
– see
Fig. 7
.
This is also the default
screen.
MAN ON
– heat is permanently on –
see
Fig. 8
.
AUTO DLY
– switches the heater
ON and OFF everyday according to
a set daily program – see
Fig. 9
.
AUTO BLK –
switches the heater
ON and OFF according to a set of
programs for weekdays only or
weekends only – see
Fig. 10.
Fig. 6
13 : 17
ON
DLY
ADVANCE
AUTO
P1
M
T
W
T
S
S
F
Fig. 7
Fig. 8
Fig. 9
Fig. 10
00 : 00
MANUAL OFF
M
T
W
T
S
S
F
00 : 00
MANUAL ON
M
T
W
T
S
S
F
00 : 00
AUTO
M
T
W
T
S
S
F
DLY
OFF
00 : 00
AUTO
M
T
W
T
S
S
F
BLK
OFF