Installation 

 

1.

 

Remove front louvred panel by removing 

three screws on top flange and one below centre of 
louvre panel. 
 
 
 

2.

 

Remove the mounting bracket and mark off 

the screw positions on the wall or ceiling.  Fix the 
bracket in position by making the necessary wall 
fixings as described under the heading " Special 
Instructions on Fitting the Heater to a Wall or 
Ceiling”  
 
 
 

3.

 

Locate the heater on the mounting bracket 

ensuring that the hexagonal screws are fully 
engaged in the slots of the bracket. 
 
 
 

4.

 

It is important that the serrated metal 

washer is located between the heater wall fixing 
member and the wall mounting bracket.  Adjust 
heater to the required angle then firmly tighten the 
hexagonal headed screws using the 8mm spanner. 
 
 
 

5.

 

Connection to the fixed wiring of the 

premises should be done through an adjacent 30 
amp double-pole switch. 
 
 

6.

 

Connection from the remote control switch 

may be carried out.  Refer to circuit 1 and 2 opposite 
for removal and substitution of wires within the 
appliance. 
 
 

7.

 

Cable connection should be carried out at 

this point. Ensure the supply cables are of adequate 
current carrying capacity  and are protected by a 
suitable fuse. 
 
If the appliance is mounted in a bathroom, the 
appliance should be mounted such that no part of it 
can be touched by a person using a fixed bath or 
shower.  An isolating switch must be provided 
outside the bathroom or be of the pull-cord type. 
 
 
WARNING: THIS APPLIANCE MUST BE 
EARTHED. 
 
 

8. 

Re-secure front louvred panel. 

 
 

Summary of Contents for THORNE & DERRICK AC6

Page 1: ... drilled and plugged with Rawlplug No 10 size FIBRE inserts The plug must be located in the solid part of the wall not just in the plaster layer For panelled internal walls or ceilings it is best to locate the studding position the heater fixing bracket accordingly and use No 10 size wood screws If it is not possible to locate the studding use type M5 Rawlplug INTERSETS making the 1Omm holes with ...

Page 2: ...er to the required angle then firmly tighten the hexagonal headed screws using the 8mm spanner 5 Connection to the fixed wiring of the premises should be done through an adjacent 30 amp double pole switch 6 Connection from the remote control switch may be carried out Refer to circuit 1 and 2 opposite for removal and substitution of wires within the appliance 7 Cable connection should be carried ou...

Page 3: ... blower and illuminates neon indicator 3 Select and switches marked E and D as required Switch Cooling E 3kW heating D 3kW heating E D 6kW heating Maintenance WARNING DISCONNECT SUPPLY before carrying out maintenance AC6 Heater Circuit Diagram 1 Wiring the Remote Control Switch Circuit Diagram 2 ...

Page 4: ...h for stain removal a weak soap solution can be applied then wipe dry After Sales Service Your Dimplex Air Curtain is guaranteed for one year from date of purchase We undertake to exchange or repair free of charge within this period any part found to be defective due to a manufacturing fault This guarantee in no way prejudices your rights under common law Should you require after sales service ple...

Reviews: